![Enplus AC022K-BE-24 User Manual Download Page 18](http://html.mh-extra.com/html/enplus/ac022k-be-24/ac022k-be-24_user-manual_2414035018.webp)
- 17 -
2. Check whether there is broken of AC output cables
or low resistance connection to the earth.
Leakage current sensor
abnormal
Detection of leakage current
sensor is abnormal.
1. Shut off the leakage current protection switch of
power distribution cabinet immediately.
2. Check whether there is broken of AC output cables
or low resistance connection to the earth.
Grounding fault
Inappropriate grounding
connection of input/output
cables or inverse connection
of L/N input cables.
1. Shut off the leakage current protection switch of
power distribution cabinet immediately.
2. Check if AC input/output cables are normal, and if
inverse connection of L/N input cables.
CAN communication
abnormal
Poor connection between AC
charger and EN-GATE.
1. Check whether CAN bus connection is reliable and
correct.
Charging cable
connection abnormal
Poor connection of charging
cable with EV/Charger.
1. Check if charging cable connection is correct and
firm.
Note: If the above problems cannot be solved, please contact the seller.
4 Disposal
The packaging materials are environmentally friendly and can be recycled. Put the packaging in applicable
containers to recycle it. Do not dispose this device with the household waste. It shall be handed over to the
applicable collection point for the recycling of electrical and electronic device. For more detailed information
about recycling of this device, please contact your local city office, your household waste disposal service or
the shop where you purchased the device.