M215 Installation and Operation
2014 Enphase Energy Inc. All rights reserved.
141-00012 Rev 06
36
M215-60-2LL-S22-IG, S23-IG, or S24-IG
Microinverter Parameters
Topic
Unit
Min Typical Max
AC Parameters
Rated (continuous) AC output Power (-40 to +65
C)
W
215
Peak AC output power
W
225
Output power factor
0.95
0.99
1
Nominal AC output voltage range
240 VAC (split phase)
208 VAC (three phase)
Vrms
Vrms
211
183
240
208
264
229
Maximum AC output current at nominal voltage
240 VAC (split phase)
208 VAC (three phase)
Arms
Arms
0.9
1.1
Nominal AC output frequency range
Hz
59.3
60
60.5
Extended AC output frequency range
Hz
57
60
61
Maximum AC output over current protection device
A
20
Maximum AC output fault current & duration
Arms/cycles
1.05 Arms over 3 cycles
1.04 Arms over 5 cycles
High AC Voltage trip limit accuracy
%
2.5
Low AC Voltage trip limit accuracy
%
4.0
Frequency trip limit accuracy
Hz
±0.1
Trip time accuracy
cycles
±2
Miscellaneous Parameters
Maximum microinverters per 20 amp AC branch circuit
240 VAC (split phase)
208 VAC (three phase)
17
25
Peak inverter efficiency
%
96.5
CEC weighted efficiency
%
96.5
Static MPPT efficiency (weighted, ref EN 50530)
%
99.4
Total harmonic distortion
%
3.0
5
Ambient temperature range
C
-40
+65
Night tare loss
mW
65
Storage temperature range
C
-40
+65