WIRING INSTRUCTIONS (Hardwired LCS)
Route the LCS conduit to a nearby service panel or junction box. Use the
included ¼” trade size watertight fitting to provide a moisture-resistant seal
with the service panel or junction box. If necessary, drill a 1/2” diameter hole to
accommodate the liquid-tight fitting or use the included 1/4” NPT to 1/2” NPT
thread reducer kit.
Figure 8: Wiring the LCS
in a Junction Box
NOTE:
The three LCS service conductors
use stranded 12AWG, 75ºC copper wire. The
insulation of each conductor is color coded for
standard 240V AC installation:
Green: Ground
Black: Line 1 (120V AC to Ground)
Red: Line 2 (120V AC to Ground)
REMARQUE:
Les trois conducteurs service
la LCS utiliser multibrins 12 AWG, 75ºC fil de
cuivre. L’isolation de chaque conducteur est un
code couleur pour une installation standard de
240 VAC:
Vert:
Mise à la Terre
Noir: Ligne 1 (120VAC à Mise à la Terre)
Rouge: Ligne 2 (120VAC à Mise à la Terre)
NOTA:
Los tres conductores de servicio EVSE
utilizan cable de cobre trenzado de 10 AWG
y 75ºC. El aislamiento de cada conductor
está codificado por colores para la instalación
estándar de 240 V CA:
Verde: Tierra
Negro: Línea 1 (120V CA a tierra)
Rojo: Línea 2 (120V CA a tierra)
NOTE:
Before connecting the LCS service
conductors, please carefully read the section
of this manual titled Service Connections on
page 15. If you are unsure of the type of power
provided at the service panel, please consult
with your local utility or call your Service
Representative for assistance.
Summary of Contents for ClipperCreek LCS
Page 1: ... Model LCS User Manual A division of Enphase Energy Inc ...
Page 34: ...LCS User Manual Page 34 This page is intentionally blank ...
Page 35: ...LCS User Manual Page 35 This page is intentionally blank ...
Page 36: ...www clippercreek com 877 694 4194 ClipperCreek A division of Enphase Energy Inc ...