4. INSTALLATION REQUIREMENTS
4.1. Installer specifications
Only authorized technicians should install and maintain the product.
The technician should conform to the following qualifications:
• safety measures as well as the parts of this manual that relate to
the installation of the product;
• The technician should be aware of and comply with all applicable
local, national and international laws and regulations;
• The technician should be capable of acknowledging the potential
hazards of the product and take the necessary precautions to
protect people and property from hazard damage.
4.2. General cable specifications
The product requires a proper power cord. An ethernet cable is
recommended (not required) to connect the charge point with the
internet. Wifi and 4G (only professional) are also possible to connect
the charge point with the internet. The ethernet cable is not to be
used underground unless through a holding tube or reinforced (STP)
cable in order to prevent corrosion by moisture or rupture by ground
shifts.
Insofar as is possible, the cables should already be present and ready
to connect to the product at the start of the product installation
procedure. Use of sheathed cables is recommended when running
cables underground. Do note that the RJ45 connectors should be
connected only after feeding the cable through the grommet into the
product.
Always use shielded ethernet cable when installing.
4.3. Power cord specifications
The electrician should select the type and dimensions of the power
cord and safety components as appropriate for the installation
environment and situation, compliant with local regulations.
14