3
4
IV.
Axis™ LED Light System
Please read the instruction manual carefully before using your Enova
Headlight. Information on product use and care are stated here within.
Damages due to disregard of the instructions within this manual are not
covered under the warranty policy of Enova Illumination.
4.1 Notes on Safety
-
Do not look directly into beam of LED light. There is the possibility of
eye injury.
-
Use only Enova PP1.5 Battery Pack
or Activ™ Neck Battery with
Axis™.
-
LED
Axis™ may get warm during use but will not get hot enough to
scald or injure.
4.2 Proper Usage
-
Axis™ is designed for use in medical, dental, or veterinary settings
only.
Axis™ is intended for use in combination with Enova Loupes,
or other loupes using verified Enova adapters.
4.3 Notes on Care
Proper care and usage of the products ensure their lifespan. Misuse,
disregard for instructions, or improper care may result in breakage or
over-wear of your Enova products.
-
Handle LED system with care, and store in dust-free environment
-
Clean LED system with disinfecting cloth, and wipe with dry
microfiber cloth.
-
Note: Before cleaning, make sure LED system is entirely off and
unplugged from sources of power.
-
Note: Use moistened cloth. Do not spray disinfectant directly onto
lenses or oculars.
-
Note: Do not clean
Axis™ with alcohol or other aggressive cleaners.
4.4 Upon arrival, check product for damages and report immediately.
- Check packing slip to ensure all components of your
Axis™ system
were properly packaged. This includes the attachable light as well
as the power pack and charger.
4.5 Functional Overview of
Axis™
1. Flip-Up yellow Filter
4. Hinge for angle-adjustment
2. Cable for battery 5. Tightening filter (see below)
3. Magnetic adapter for loupe attachment
4.6 Technical Data
Lamp Type:
High-performance LED
Color Temperature:
5300 Kelvin
Lux:
30,000
(at 12”/30cm)
Weight:
0.25 ounces/7 grams
4.7 Mounting your
Axis™ Light
Below are instructions for how to mount your
Axis™ on Enova TTL. For
instructions on how to mount your
Axis™ on other loupe models, please
contact an Enova representative.
-
Ensure that Loupe has magnetic adapter secured to frame, with
notches of magnet pointing in down.
-
Take
Axis™ with cable at the top, and gently secure the magnetic
adapter (3) to magnet on brim of loupe frame.
-
Adjust angle of
Axis™ such that it is co-axial with eyes and
illuminates the entire field of view through the loupe telescopes.
-
Secure the cable to the fasteners on the temple arm of the glasses.
-
Tighten hinge of filter (5) using provided screwdriver. Be gentle as
the components are very small. Tighten as you would a normal
screw, until filter moves up and down at your desired resistance.
WARNING: Do not Over-loosen filter, as small internal
components may be lost
4.8 Clean using provided Enova alcohol-free cleaner solution and provided