The self-priming electric pump with rubber impeller is suitable for the transfer of delicate food liquids even in the
presence of suspended bodies (such as wine, milk, oil, de-stemmed grapes, fruit juices), and a wide range of
chemical substances.
The electro pump is able to work in both directions of rotation. The pump body is made entirely of AISI 304
stainless steel, while the impeller is made entirely of rubber for food use (Certificate N° 2218 del 05/11/98; N°
2218/b del 05/11/98; N° 2844 del 30/11/98 in accordance with D.M. del 21/03/73 e D.M. n° 220 del 26/04/93).
In the COAXIAL and with INVERTER models the pump is connected directly to the crankshaft, while in the
"BELT TRANSMISSION" models the pump is connected to a pulley connected to the engine with transmission
belts; on the MECHANICAL VARIATOR and REDUCER models the pump is connected to a cardan shaft.
In each model the pump can be easily opened to allow ordinary cleaning and maintenance operations to be carried
out by the qualified staff.
The models EURO 20, EURO 30, EURO 40, EURO 50, EURO 60 can be provided with BY-PASS: a valve in
stainless steel AISI 304 is placed externally to the body pump, which allows you to adjust the pressure as you like.
It is not to be used to regulate the flow, but it allows to close the outlet pipe and let the product recycle for a few
seconds avoiding overloads to the engine (ATTENTION max 10 sec. to avoid problems of overheating and / or
damage to the product).
The electric pump consists of the following components:
-ENGINE
-TROLLEY (optional in the coaxial models)
- MOTOR PULLEY (where provided)
-PUMP PULLEY (where provided)
- BELT (where provided)
-PUMP SUPPORT
-RUBBER IMPELLER
-MECHANICAL SEAL
- STAINLESS STEEL DISC
- STAINLESS STEEL SHAFT
-ELECTRICAL PANEL
The electric pump must be positioned firmly in a stable and horizontal position with respect to the ground (operate
the brake of the wheels in the models provided with them), and the level of the liquid to be transferred must be at a
maximum depth not exceeding 5/6 meters from the axis of the pump, and the aspiration system must be below the
liquid level of at least 10-15 cm.
Checks before installation: before connecting the machine, make sure that the motor voltage (shown on the plate)
corresponds to that of the mains and that the switch is set to the "Zero" stop position. The electrical safety of this
machine is allowed only if it is connected to an effective earthing system, performed according to current electrical
standards. The verification and possible installation of the appropriate electrical components must be carried out by
qualified staff. Furthermore, the use of multiple sockets or adapters is not recommended; if their use is
1. DESCRIPTION
2. POSITIONING, CHECKS AND INSTALLATION