AFTER MAINTENANCE ACTIONS
Once the new thermostat is installed, it will be nece-
sary to ensure that it operates at the required and appropriate
ranges. The new thermostat has an adjustment that can be
turned using a small flathead screwdriver. Several cycles will
need to be run on the unit while observing the final rinse tem-
perature. The thermostat needs to cycle so that the final rinse
water meets the indicated minimums on the machine data
plate for every cycle.
SPECIAL NOTES
Work performed on Jackson dishmachines by unau-
thorized or unqualified personnel may void the warranty.
Before beginning this or any other maintenance evolution on
a unit under warranty, you should contact a certified Jackson
technician or Jackson Technical Service. You can find a list of
qualified service agencies in the back of you unit’s installation
manual.
SPECIAL PARTS
Thermostat Replacement Kit: 06401-003-13-94*
*The kit contains a thermostat, imperial brass fitting,
jumper wires and instructions.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 06-26-2006 Revised: N/A
SECTION 5: SERVICE PROCEDURES
RINSE REGULATINGTHERMOSTAT REPLACEMENT INSTRUCTIONS (CONTINUED)
31
Calibrating the new thermostat.
Summary of Contents for TEMPSTAR
Page 2: ......
Page 7: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 14: ...8 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 19: ...13 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 21: ...15 SECTION 4 TROUBLESHOOTING SECTION ...
Page 24: ...18 SECTION 5 SERVICE PROCEDURES ...
Page 38: ...32 SECTION 6 PARTS SECTION ...