10. There is no need to rewire the wash motor as it is wired
single phase on all models, regardless of phase.
11. Once the heaters are rewired, it is necessary to put the
supplementary decal on the unit next to the machine date
plate. The machine data plate can be found, when looking at
the unit from the front, under the tub lip on the right side. DO
NOT REMOVE THE DATA PLATE! Place the supplementary
decal next to the data plate so that it can be seen by servicers
and operators. This decal is required to inform others that this
maintenance action has been performed and that the electri-
cal characteristics of the machine have been changed.
12. Refer to the drawings below for an example of how to
place the supplemental decal.
AFTER MAINTENANCE ACTIONS
1. Replace all heater covers and then restore power
to the unit. Using an amperage meter, verify the amperage
draw on the heaters is within acceptable parameters (per
local, state and national codes). If amperage loads are outside
acceptable ranges, the unit should not be operated and the
source of the problem should be determined by a qualified
technician. If any problems arise you can contact Jackson
Technical Service.
SPECIAL NOTES
1. Work performed on Jackson dishmachines by
unauthorized or unqualified personnel may void the warranty.
Before beginning this or any other maintenance evolution on
a unit under warranty, you should contact a certified Jackson
technician or Jackson Technical Service. You can find a list of
qualified service agencies in the back of you unit’s installation
manual.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 06-26-2006 Revised: N/A
SECTION 5: SERVICE PROCEDURES
TEMPSTAR PHASE CONVERSION INSTRUCTIONS (CONTINUED)
27
TEMPSTAR
60Hz 1 PH 2 WIRE
TOTAL LOAD
WASH HEATER:
WASH MOTOR:
4.1 KW
¾ HP
5.7 AMPS
208 VOLT
19.7 AMPS
68.7 AMPS
21.7 AMPS
5.7 AMPS
230 VOLT
75.2 AMPS
¾ HP
5 KW
SERIAL NO.:
MODEL:
180°F
150°F
45 SEC
11 SEC
140°F MIN
20 PSI
MINIMUM WASH TEMPERATURE
MINIMUM RINSE TEMPERATURE
WASH CYCLE TIME
RINSE CYCLE TIME
INCOMING WATER TEMPERATURE
OPTIMUM FLOW PRESSURE
RINSE HEATER:
9 KW
43.3 AMPS
47.8 AMPS
11 KW
An
60Hz 3 PH 3 WIRE
TOTAL LOAD
WASH HEATER:
WASH MOTOR:
4.1 KW
3/4 HP
5.7 AMPS
208 VOLT
11.4 AMPS
42.1 AMPS
12.6 AMPS
5.7 AMPS
230 VOLT
45.5 AMPS
3/4 HP
5 KW
MODEL: TEMPSTAR
RINSE HEATER:
9 KW
25.0 AMPS
27.2 AMPS
11 KW
An
Company
09905-003-16-54A
Machine Data Plate (Example)
Supplemental Decal (Example)
SPECIAL PARTS
Kit, 1 to 3 phase, 208-230v/50hz, conversion:
06401-003-15-59
Kit, 3 to 1 phase, 208-230v/50hz, conversion:
06401-003-16-60
Kit, 1 to 3 phase, 208-230v/60hz, conversion:
06401-003-16-61
Kit, 3 to 1 phase, 208-230v/60 hz, conversion:
06401-003-16-62
Note:
Ensure that the supplementary decal that you place on
the unit has the same heater characteristics as the unit marked
on the data plate. Your kit comes with decals for both 12KW
and 14KW rinse heaters!
Summary of Contents for TEMPSTAR
Page 2: ......
Page 7: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 14: ...8 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 19: ...13 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 21: ...15 SECTION 4 TROUBLESHOOTING SECTION ...
Page 24: ...18 SECTION 5 SERVICE PROCEDURES ...
Page 38: ...32 SECTION 6 PARTS SECTION ...