4.4
Connection between Segger J-Link and PTM 535
PTM 535 has to be connected to the Segger J-Link connector for configuration. Figure 9
below shows the pin-out of the Segger J-Link connector.
Figure 9
–
Segger J-Link connector pin-out
Two approaches can be used to connect Segger J-Link and PTM 535 depending on the pow-
er supply of PTM 535 during configuration. Both approaches are described below.
4.4.1
Segger power supply (6-Pin interface)
Supplying power by Segger J-Link to PTM 535 is the recommended approach. It requires a
6 pin test interface.
In this case, power is supplied by Segger J-Link to PTM 535 via PTM 535 MP5 (V+) con-
nected to Segger Pin 19. The
“5V Target Power Supply”
option has to be activated at the
Segger user interface. We recommend checking available voltage supply.
The required connections are shown in Figure 10 below.
Figure 10
–
6-Pin configuration interface (Power supplied by Segger)