EnOcean BootUp EnO868SELV Installation And Operating Instructions Manual Download Page 6

 

               

         

 

Repeater-EnO868SELV

 

EnOcean Repeater 868 MHz 

Repeater-EnO868USB

 

Read the operating instructions carefully before commissioning.

 

Installation and operating instructions

 

Rev.: February 2016 

Repeater-EnO868_104126_OperationManual_E_FEB2016.doc/pdf 

Page 6 of  7 

BootUp GmbH 

|

 Sonnenbergstrasse 23 

|

 CH-5236 Remigen 

|

 Switzerland 

|

 Phone +41 56 284 09 21 

|

 Fax +41 56 284 09 22 

 2016  

|

  Omi technical changes excepted 

|

   

www.BootUp.ch

   

|

   

www.myHomeControl.ch

 

|

[email protected]

 

High frequency emissions from radio sensors 

An expert opinion from the Institute for Socio-Ecological Research and Education (ECOLOG) has confirmed that 
the  high-frequency  emissions  of  radio  switches  and  sensors  with  EnOcean  technology  are  significantly  lower 
than  comparable  conventional  switches.  In  addition,  due  to  the  reduced  wiring  of  radio  switches,  potential 
exposure  to  low  frequency  magnetic  fields  radiated  over  the  line  is  reduced.  If  one  compares  the  radio 
emissions of the radio switches with other radio frequency sources in the building, e.g. DECT phones and base 
stations, these systems are a factor of 1500 above those of the radio switch. 

Download 

Ecolog Report on EnOcean Frequency Emissions (PDF).

  

www.enocean.com/fileadmin/redaktion/pdf/articles/ECOLOG_measuringreport_v1.2.pdf

 

Warranty conditions 

These  operating  instructions  are  part  of  the  device  and  the  guarantee  conditions.  It  is  to  be  presented  to  the 
user. The technical design of the devices may change without prior notice. BootUp products are manufactured 
and  quality-tested  using  state-of-the-art  technology  in  accordance  with  applicable  national  and  international 
regulations. In the event of a defect, you can send the device to your dealer along with a clear description of the 
claim  (type  of  use,  defect  detected,  etc.).  Claims  for  defects  shall  be  settled  in  accordance  with  the  current 
delivery  and  payment  conditions  of  BootUp  GmbH.  The  processing  of  warranty  claims  is  governed  by  Swiss 
law. 

Additional information 

Further  information  on  the  application  with  the  BootUp  SW 

myHomeControl

,  the  EnOcean  extension  for 

visualization  and  control  tasks  in  building  services,  test  equipment  for  radio  quality  measurement  and  other 
EnOcean devices, visit 

www.myHomeControl.ch

Customized versions / firmware update:  

It  is  possible  to  load  a  custom  firmware  on  this  device  (TCM300).  A  corresponding  programming  interface  is 
available.  A  firmware  update  in  the  field  is  not  provided.  It  is  also  possible  to  design  the  connection  cable 
according to customer requirements. If you are interested, please contact us. 

Feedback is welcome 

If you are satisfied with this product and this data sheet, please share it to others. If you are not satisfied, miss 
information, have corrections or suggestions for improvement, then we look forward to receiving an email. Many 
Thanks. 

Manufacturer  

BootUp GmbH, Sonnenbergstrasse 23, CH-5236 Remigen, Switzerland   

www.BootUp.ch

        

www.myHomeControl.ch

        

[email protected]

  

 

 

 

 

 

 

 

 

 

Trademarks belong to their owners. 

Summary of Contents for BootUp EnO868SELV

Page 1: ...ice the range between EnOcean transmitters and receivers can be increased The radio signal can be cascaded to the receiver via a maximum of two repeaters A configuration or teach in is not required Also as a replacement for radio range problems in existing installations This device is identical and replaces the predecessor RepeaterEnO868USB Article No 104107 and RepeaterEnO868SELV Article No 10410...

Page 2: ... The products may be sold and operated free of registration and toll free in the countries of the European Union the CH IS and N Installation instruction The designer plastic housing is prepared for direct surface mounting wall or ceiling The housing does not have to be opened for mounting The device can be hung in screwed in screws Two blind holes at a distance of 55 mm are provided on the unders...

Page 3: ... of operation settings via switches Lower side of the device LEDs show the operating state Switch is used for settings Operating status display green LED Power is on when device is powered yellow LED Radio flashes for each received radio signal even if the signal is not amplified Settings via switch Repeater Function Deactivate Activate In position Rep OFF is the Repeater function switched off onl...

Page 4: ...t voltage 100 to 240 V AC 10 150 mA 50 to 60 Hz Output voltage 6V DC 1000mA ripple 300 mVpp current limited sustained short circuit proof standby 0 3W Standards Fulfils Class II SELV for the following applications EN 60950 IEC 60950 UL 60950 VDE CE EMC Conforms to EN 55011 55014 EN 55022 B EN 55024 FCC 41 part 15 EN 61000 3 2 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 6100...

Page 5: ...n of the installation and during optimization or troubleshooting the EnOcean signals can be easily and reproducibly simulated and measured with test equipment e g P30 see www probare biz Please visit www myHomeControl ch Fault diagnosis error analysis and rectification For a new plant or an existing plant Check whether the green Power LED is lit Check the reception function by sending press PTM bu...

Page 6: ...resented to the user The technical design of the devices may change without prior notice BootUp products are manufactured and quality tested using state of the art technology in accordance with applicable national and international regulations In the event of a defect you can send the device to your dealer along with a clear description of the claim type of use defect detected etc Claims for defec...

Page 7: ...868MHz 104123 USB EnO868 Stick ESP3 0 USB EnOcean TranceiverStick Modem ESP3 0 868MHz 104180 RS232 ESP3 868MHz Model Type Description Article No RS232 Rep EnO868 ESP3 0 RS232 EnOcean Gateway Modem Bidirektional ESP3 0 868 MHz 104116 RS485 ESP3 868MHz Model Type Description Article No RS485 Rep EnO868 ESP3 0 RS485 EnOcean Gateway Modem Bidirektional ESP3 0 868 MHz 104114 Repeater 868MHz Model Type ...

Reviews: