![England's Stove Works 30-NCG Installation & Operation Manual Download Page 5](http://html.mh-extra.com/html/englands-stove-works/30-ncg/30-ncg_installation-and-operation-manual_2413077005.webp)
5
CAUTION
If you have any doubt concerning your ability to complete your installation in a professional-like
manner after reading these instructions, you should obtain the services of an installer who is versed in
all aspects as to the correct and safe installation.
Do not
use temporary, makeshift compromises
during installation.
BEFORE INSTALLATION OF YOUR APPLIANCE
1.
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
2.
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS.
3.
Check with the building inspector’s office for compliance with local codes; a permit may be
required.
4.
This appliance requires a masonry or prefabricated chimney listed to ULC S629 (Canada) and
UL103HT (U.S.) sized correctly.
5.
A 6” diameter flue is required for proper performance.
6.
Always connect this unit to a chimney and
NEVER
vent to another room or inside a building.
7.
DO NOT
connect to any duct work to which another appliance is connected, such as a
furnace.
8.
DO NOT
connect this unit to a chimney flue serving another appliance.
9.
DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
10.
The connector pipe and chimney should be inspected periodically and cleaned if necessary.
11.
Remember the clearance distances when you place furniture or other objects within the area.
DO NOT
store wood, flammable liquids or other combustible materials too close to the unit.
12.
Contact your local fire authority for information on how to handle a chimney fire. Have a
clearly understood plan to handle a chimney fire. In the event of a chimney fire, turn air control
to a closed position and
CALL THE FIRE DEPARTMENT.
13.
DO NOT tamper with the combustion air control beyond normal adjustment.
14.
Once the required draw is obtained, operate only with doors closed; open doors slowly when
re-fueling (this will reduce or eliminate smoke from entering the room).
15.
Visit our web site at
www.heatredefined.com
for helpful information, frequently asked
questions, parts/accessory orders and more.
Customer Service: (800) 245-6489.
Note on Outside Air Hookup:
You can use an outside air hookup with this unit. We highly recommend it for
homes built since the more air-tight construction standards went into effect. This involves connecting a metal pipe
(usually three inches (3”) in diameter - check your stove - and the pipe can be flex or rigid) from the air inlet pipe
located on the bottom rear of the stove through your floor or wall. The outside end of this pipe should be covered
in some manner (i.e. with a screen) to keep it clear of foreign matter. Be sure to keep it above the snowdrift line
and clear of leaves and other debris.
It is necessary to use this hookup if installing in a mobile home or
double-wide – See “Outside Air Connection” section of manual.
A kit is available from England’s Stove Works, Inc. designed for connecting this unit to outside
combustion air. [Part No. AC-OAK3]