3
4
-
4.
Remove the screws, and then remove the cover.
5.
Drain the fuel from the carburetor by loosening the drain screw on the
carburetor float chamber.
6.
Turn the 3 in 1 switch to “OFF”.
7.
Tighten the drain screw.
8.
Install the cover and tighten the screws.
9.
Turn the fuel tank cap air vent knob to “OFF” after the engine has
completely cool
ed
down.
TIP:
•
Do not connect with any electrical devices. (unloaded operation)
•
Duration of the running engine depends on the amount of the fuel left in
the tank.
3. Start the engine ( See Page 20 ) and leave it run until it stops. The engine
stops in approx. 20 minutes. Time by running out of fuel.
8.2 Engine
Perform the following steps to protect the cylinder, piston ring, etc. from
corrosion.
1.
Remove the spark plug, pour about one table- spoon of SAE 15W-40 into
the spark plug hole and reinstall the spark plug. Recoil start the engine by
turning over several times (with 3 in 1 switch knob off) to coat the cylinder
walls with oil.
2.
Pull the recoil starter until you feel compression. Then stop pulling. (This
prevents the cylinder and valves from rusting).
3.
Clean exterior of the generator. Store the generator in a dry, well-
v
entilated
place, with
a
cover placed over it.