6.10 Spesifikasjoner – kabel, sikring og batteri
XForce
Thruster
Motor
V/kW
Thrust
(KG)
Maximum kabel
lengde
1)
Minimum kabel dim.
Anbefalt min.
batteri kapasitet
Anbe
falt
sikr.
amp.
Sikring
art. nr.
Lengde m/ft
Dim.
2)
mm
2
-
AWG
Ah/V
CCA
(SAE)
XF20
12/1.1
20
1-5/1-16
50-1/0
50Ah/12V
550
200
12-00200
XF40
12/2
40
1-4/1-13
4-8/13-26
50-1/0
70-2/0
100Ah/12V
800
300
12-00300
XF60
12/4
60
1-10/1-33
10-20/33-67
95-3/0
120-4/0
100Ah/12V
800
350
12-00350
XF60
24/4
60
1-10/1-33
10-20/33-67
95-3/0
95-3/0
100Ah/24V
800
300
12-00300
XF75
12/4
75
1-10/1-33
10-20/33-67
95-3/0
120-4/0
100Ah/12V
800
400
12-00400
XF75
24/4
90
1-10/1-33
10-20/33-67
95-3/0
95-3/0
150Ah/24V
1050
350
12-00350
XF90
12/4
90
1-10/1-33
10-20/33-67
95-3/0
120-4/0
100Ah/12V
800
400
12-00400
XF90
24/4
90
1-10/1-33
10-20/33-67
95-3/0
95-3/0
150Ah/24V
1050
350
12-00350
XF130
24/7
130
1-10/1-33
120-4/0
175Ah/24V
1150
400
12-00400
1. Avstanden mellom thruster enheten og batteri, en vei for hver kabel.
Ved å benytte kabler med enda større tverrsnitt vil det oppnås økt skyvekraft.
2.
Krav til kabelisolasjon er minimum 105
0
C (221
0
F).
Summary of Contents for XForce Series
Page 24: ...XF Rev 5 2008 10 06 Side 24 6 11 Elektriske kobling skjemaer 6 11 1 XForce 20 ...
Page 25: ...XF Rev 5 2008 10 06 Side 25 6 11 2 XForce 40 60 75 90 130 ...
Page 32: ......
Page 56: ...XF Rev 7 2008 10 14 Page 24 7 10 Wiring diagrams 7 10 1 XForce 20 ...
Page 57: ...XF Rev 7 2008 10 14 Page 25 7 10 2 XForce 40 60 75 90 130 ...
Page 64: ......