If the programmed start time is before the end time, output #1 is auto-disabled within a single
day. If the programmed start time is after the end time, the end time will be on the
following day.
•
The start time and end time cannot be the same.
•
The auto-disable time can be temporarily paused and restarted using the super user code (see
“Programming the Super User Code” on pages 14~15).
•
During the output #1 auto-disable time, the super user code can be used to operate output #1
•
The red LED will remain lit during the output #1 auto-disable time.
When programming the output #1 auto-disable time, use this general formula:
56 HHMM HHMM #
56
– Program Output #1 Auto-Disable Time
HHMM
– Start Time
HHMM
– End Time
Start Time:
•
Start time for output #1 auto-disable time.
HH
represents hours and
MM
represents
minutes in the military (24-hour) time format, from 00:00 to 23:59.
End Time:
•
End time for output #1 auto-disable time.
HH
represents hours and
MM
represents
minutes in the military (24-hour) time format, from 00:00 to 23:59.
Examples (in these examples, assume that the super user code is
2580
):
•
In programming mode, set the output #1 auto-disable time from 12:00 PM to 1:00 PM:
56 1200 1300 #
•
In programming mode, set the output #1 auto-disable time from 6:30 PM to 7:30 AM the
following day:
56 1830 0730 #
•
In programming mode, clear the output #1 auto-disable time:
56 #
•
Temporarily pause and resume the output #1 auto-disable time:
2580 # 8
•
Activate output #1 during the auto-disable time (i.e. open the protected door):
2580 # 1