![ENFORCER SK-1123-SDQ Manual Download Page 29](http://html1.mh-extra.com/html/enforcer/sk-1123-sdq/sk-1123-sdq_manual_2412010029.webp)
29
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Programming the Egress Delay/Warning (cont.):
Examples:
1.
Momentary mode
– Press the egress button, and the keypad will beep for 5 seconds before
output #1 activates:
90 2 5 #
2. Hold button to activate
– Press and hold the egress button for 10 seconds, and the keypad will
beep for those 10 seconds before output #1 activates:
90 5 10 #
3. Return to default setting – Press the egress button to activate output #1 with no beeping or
delay:
90 1 0 #
NOTE: For safety and to avoid confusion, when a delay or a press-and-hold delay is programmed,
please post a notice near the egress button, such as: “Press and hold the button for 5 seconds or
until the door is unlocked.”
Direct Access to Programming (DAP):
Direct Access to Programming (DAP) is used to reset the master code if it is forgotten. DAP will not
change the programming of the keypad in any other way.
To Use DAP:
1.
Disconnect the keypad’s power.
2. Wait one minute to ensure that the keypad’s power is fully discharged.
3. Reconnect the power. The keypad will beep repeatedly for one minute.
4. While the keypad is beeping, press the egress button once to stop the beeping.
5.
Enter the DAP code:
2828 **
6.
The amber LED will now turn ON, indicating that the keypad is ready for a new master code to
be programmed.
NOTE:
•
See “Programming the Master Code” on page 13 for how to program a new master code.
•
Direct Access to Programming (DAP) will not reset the keypad’s programming. It will only enter
programming mode in order to program a new master code.
•
For system reset, see page 13.