702-000250-01
-5-
Enerwatt Battery Chargers also provide a battery equalisation function.
What does this feature do?? – Equalisation helps to maintain and balance your battery cells by reversing the
high concentration of electrolytes from the bottom of your battery.
This allows all the cells to charge evenly and makes you get the most out of your battery.
You can you this feature weekly to ensure your battery is always well maintained.
Note: The Equalisation process will not work for GEL Batteries.
To manually activate this equalisation feature, simply press and release the ‘Equalisation’ Button and the
Equalisation LED will turn ON (RED).
Depending on the charge rate selected, this process will time out after 4 to12 hours.
Equalising voltage is set to 15.5V for AGM / WET Conventional batteries and 16.2V for Odyssey 310-925
batteries.
To manually exit the ‘Equalisation’ mode, simply Press and Release the ‘Equalisation’ Button again and the
Equalisation LED will turn OFF.
For manual equalisation, always refer to your battery manufacture’s recommendations / specifications.
4. Disconnecting the Battery charger from Battery.
(a) If the Battery is out of the vehicle.
1.
Switch OFF and Remove the AC Power Socket from the outlet.
2.
Remove the Black lead and then the Red lead.
3.
Check electrolyte levels if possible. (As they may need topping up with distilled water after
charging)
(b) If the Battery is in the vehicle.
1.
Switch OFF and Remove the AC Power Socket from the outlet.
2.
Remove the lead from the vehicle chassis.
3.
Remove the lead from the battery.
4.
Check electrolyte levels if possible. (As they may need topping up with distilled water after
charging)
CHARGING STAGES
Note: The Charger automatically switches off after 24 hours if the Bulk charge cycle is not completed.