Installing the cooker hood using OFF
mounting option
The Enervent ventilation unit and the cooker hood are
installed as separate units. Install the ventilation unit
according to its installation instructions.
•
Install the cooker hood according to the
manufacturers instructions.
•
Install the cooker hood extraction duct to the
Enervent ventilation unit cooker hood duct
connection The Neo ventilation unit duct connection
cap must be opened using a sharp knife or a
finethooted saw.
•
Connect the cable from the cooker hood to the
Enervent ventilation unit according to the electrical
schematic.
The duct material, duct insulation and duct installation
must comply with local laws and legislation regarding
air removal from cooking areas.
Install the extraction duct so that it can be easily
cleaned.
If a flexible duct is used, be sure to attach the duct
properly to prevent creasing. See picture below.
FOR YOUR INFORMATION
FOR YOUR INFORMATION
FOR YOUR INFORMATION
Opening the cooker hood duct connection on
the Neo ventilation unit.
Installation of Standard cooker hood
The cooker hood can be installed under a cupboard or
between cupboards.
Attaching the extract duct
Connect the cooker hood to a Ø125 mm duct.
The duct coupling assembly is delivered inside the cooker
hood.
Remove the grease filter.
The damper flap rod A is inserted into the collar under the
damper flap. Make sure the locating pins B fit under the
sheet metal edge and that the coupling assembly locks
firmly into place.
Kuva 4
Liesikupu voidaan asentaa myös konsolien
avulla, joita on saatavana lisävarusteena,
Kuva 4. Lisävarusteiden asennusohjeet ovat
lisävarusteiden mukana.
Liitäntä poistoilmakanavaan
Yhdistä liesikupu putkella Ø125 mm.
Kuva 5
Huom!
Jos asennukseen käytetään liitosletkua,
se on asennettava kiinteästi lähimpään
liitoskohtaan, Kuva 5.