81
Operating and maintenance instructions for the ventilation unit
3
SimultaLTR-3usly press buttons
and
once.
eWind info list
Marking
Definition
n0
Standard mode is on
n1
Boosted ventilation for the removal of
humidity
n2
Boosted ventilation for the removal of carbon
dioxide
n3
Heat recovery is on
n4
Post-heating with an electric or water coil is
on
n5
Outdoor air pre-heating with CHG/AGH or an
electric pre-heater is on
n6
Supply air CG, CHG, or AGH cooling is on
n7
Cold recovery with the rotating heat
exchanger is on
n8
Ventilation boosted manually
n9
Away mode is on
n10
Dehumidification with rotor is on
n11
Defrosting is on
n12
Eco mode is on
n13
Maintenance reminder: the time remaining
until the next filter replacement in days
n14
Unit is starting
1
SimultaLTR-3usly press buttons
and
once.
•
Parameter (n1..nn) is displayed.
2
Browse the info list using buttons
and
.
Return to the standard view:
eWind info list
Opening:
Data display
You can view the available functions in the eWind info list on the data display.
If you do not press any button, the menu will
close in 5 minutes and the panel will return to the
standard view.
FOR YOUR INFORMATION
Summary of Contents for eWind LTR-3
Page 15: ...15 Ilmanvaihtolaitteen k ytt ja yll pito ohje Suodattimien vaihto 4 2 3 1 LTR 3 eWind E F7 F5...
Page 24: ...24 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI LTR 3 A 45 dB 230 m3 h...
Page 25: ...25 Drift och underh llsanvisningar f r ventilationsaggregatet...
Page 26: ...26 LTR 3 eWind Drift och underh llsanvisningar f r ventilationsaggregatet Svenska...
Page 48: ...48 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI LTR 3 A 45 dB 230 m3 h...
Page 49: ...49 Drifts og vedlikeholdsinstrukser for ventilasjonsenheten...
Page 50: ...50 LTR 3 eWind Drift och underh llsanvisningar f r ventilationsaggregatet Norsk...
Page 72: ...72 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI LTR 3 A 45 dB 230 m3 h...
Page 73: ...73 Drifts og vedlikeholdsinstrukser for ventilasjonsenheten...
Page 74: ...74 LTR 3 eWind Operating and maintenance instructions for the ventilation unit English...
Page 96: ...96 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI LTR 3 A 45 dB 230 m3 h...
Page 97: ...97 Operating and maintenance instructions for the ventilation unit...
Page 98: ......
Page 99: ......