Ethernet Module
Sinus H
37
6.3 Explicit Message
A non-periodic communication method used for reading or writing
the attribute value of the Inverter or Ethernet/IP.
The UCMM method which can communicate data between
Originator and Target without connection, and a periodic data
communication method using Class 3 Connection are available.
6.4 Supported Object
①
Identity Object (Class 0x01, Instance 1)
[Attribute]
Attribute
ID
Access
Attribute Name
Data
Length
Attribute
Value
1
Get
Vendor ID
(Enertronica Santerno
S.p.A.)
Word
259
2
Get
Device Type (AC Drive)
Word
2
3
Get
Product Code
Word
10
note 1)
4
Get
Low Byte - Major
revision
High Byte - Minor
revision
Word
note 2)
0x0102
5
Get
Status
Word
note 3)
6
Get
Serial Number
Double
Word
note 4)
7
Get
Product Name
12 Byte
Sinus H
Ethernet
Note 1) Product code
‘
6
’
means Sinus H AC drive.
Note 2) The Upper and Lower byte represent the Major Revision
and Minor Revision, respectively. For example, 0x0102 means
2.01. The version of the Ethernet communication is indicated in
the Keypad CM- 6 FBus S/W Ver.