www.enersys.com Publication No. US-FL-IOM-002 January 2007 Page
21
SPACER
(OPTIONAL)
CELL/JAR PLACEMENT
Figure 7.2
5.
If provided, place the long rubber angle cell spacer on
the mid-point of the cell cover. Position one leg on top
of the cover and the other so that it extends down over
the edge of the cover to the side where the next cell/jar
is to be positioned. See Figure 7.2.
6.
Lift the next cell/jar to be installed and place it next to
the previously installed unit. See Figure 7.3. Be certain
to allow proper spacing between cells/jars as outlined
in Section 7.2.2. Observe proper polarity orientation.
Exercise extreme care when positioning cells.
Bumping or scraping a cell against the adjacent
cell/unit or rack member may damage the jar
material.
Do NOT use any kind of tool to pry cells into position.
CELL/JAR PLACEMENT
Figure 7.3
7.
Remove the belt loops (if used) from the lifting hook and
pull the belt free from under the unit. Also remove any
remaining protective packing covers. See Figure 7.4.
Move cell into final position, observing spacing
requirements.
CELL/JAR PLACEMENT
Figure 7.4
Summary of Contents for PowerSafe Data Safe