background image

1. Features ............................................................................................5
2. Technical  Information .....................................................................5
3. Safety Precautions ..........................................................................6
4. Installation .......................................................................................6
5. Operating Instructions ...................................................................7
6. Fault codes.......................................................................................9
7. Service and Troubleshooting  ........................................................9

1.1. 

Microprocessor-controlled

1.2. 

Able to auto identify battery’s capacity

1.3. 

Able to adapt to State of Charge (SoC)

1.4. 

Compatible with battery voltages of:

1ph

3ph

12V

24V

24/36/48V

36/48V

72/80V

96V

120V

 

1.5. 

Unique profile for charging Thin Plate Pure Lead (TPPL) 

1.6. 

Unique profiles for NexSys

®

 battery charge applications: NXBLOC; 

NXSTND.

1.7. 

Fully programmable to unique fleet requirements.

1.8. 

Battery chemistry agnostic - TPPL, Flooded and Gel Lead Acid.

2.1.   Name plate labels

2.1.1.   Name plate label definitions

1. Features

TABLE OF CONTENTS

2. Technical  Information

BATTERY CHARGER 

INSTRUCTIONS FOR USE

ENGLISH

2

Item

Description

Serial Number

Provides date code.

Hertz 

Input voltage frequency. Under no conditions operate  

the charger at a different frequency or from a generator  

with unstable frequency.

Phase

TCX. When “1” indicates a Single Phase Charger  

and “3” indicates a Three Phase Charger.

AC Volts

Nominal voltage for which this charger is rated to operate.

DC Volts

Nominal DC output voltage of the charger

Modules

Actual number of power modules installed  

in the charger cabinet.

DC Amps

DC current that this charger will deliver to a discharged 

battery with the number of power modules installed  

and based on the Nominal Voltage

2.1.2.   Output power letter codes

Output Power 

(kW)

Number 

Modules

Module Power 

(kW)

1.0

1

1.0

2.0

2

1.0

3.0

3

1.0

3.5

1

3.5

7.0

2

3.5

10.5

3

3.5

14.0

4

3.5

17.5

5

3.5

21.0

6

3.5

24.5

7

3.5

28.0

8

3.5

2.1.3.   Cabinet size (number of modules available) and DC cable size

Phases

Module 

Positions

Standard 

Cable Gauge

Comments

1ph

Max 1

6 mm

2

stand alone cabinet

1ph

Max 3

25 mm

2

Three slot, 3 kW cabinet

3ph

Max 2

35 mm

2

Two slot, 7 kW cabinet

3ph

Max 4

70 mm

2

Four slot, 3.5 to 14 kW cabinet

3ph

Max 6

95 mm

2

Six slot, max 21 kW cabinet

3ph

Max 8

70 mm

2

 

or 1 x 95 

mm

2

Eight slot, max 28 kW cabinet.

Dual cable for 24/36/48Vdc single 

cable for 72/80Vdc

TC3 IMP

Reviews: