![Enerpac L1697 Instruction Sheet Download Page 6](http://html1.mh-extra.com/html/enerpac/l1697/l1697_instruction-sheet_2411201006.webp)
3. Open the jaws to the desired spread.
Place the cylinder control valve lever in the “Oil Supply” position, place the cage
control valve lever in the “Jaw Open” position, and activate the pump by placing the
remote jog switch in the “On” position. Release the remote jog switch when the jaws
have reached the correct spread.
To close jaws, place the cylinder control valve in the oil supply position,
place the cage control valve lever in the “Jaw Control” position, and
activate the pump by placing the remote jog switch in the “On” position.
4. Adjust jaw tips so the jaws will pull on a flat surface.
Always use the maximum pulling surface of the jaw. Adjust the jaw tips by turning the
1
1
/
4
" cap screw. To angle tip inward, turn the cap screw clockwise. To angle the tip
outward, turn the cap screw counterclockwise. Before pulling, always ensure that the
machined caps are properly fitted to the curved surface.
5. Extend the 100-ton cylinder.
Place the 100-ton cylinder control valve in the “Extend” position and activate the
pump by placing the remote jog switch in the “On” position.
To retract cylinder, place the 100-ton cylinder control valve in the “Retract” position.
The cylinder will retract automatically without activating the pump.
Changing The Jaw Spread (100-Ton Pullers only)
If opening/closing the jaws using the standard cage setting does not provide enough
spread or does not provide enough closure,use the following adjustments to achieve the
maximum and minimum spreads.
1. Support the jaws.
2. Remove 6 cap screws, lock washers and nuts on 1 jaw guide at a time.
3. Slide jaw guide inward/outward on cage 1 bolt hole.
4. Replace 4 cap screws, lock washer, and nuts and tighten appropriately.
5. Reverse this process to return to standard jaw spread.
(6)
Default jaw guide position
when puller is shipped.
Jaw guide moved 1 bolt hole
OUT
to increase spread.
Jaw guide moved 1 bolt hole
IN
to decrease spread.
Summary of Contents for L1697
Page 8: ...Notes 8...
Page 16: ...Notes 16...
Page 24: ...Notes 24...
Page 32: ...Notes 32...
Page 40: ...Notes 40...
Page 48: ...Notes 48...
Page 50: ...50 2 7 10 0 3 0 4 1 40 15 T T 50 2...
Page 51: ...51 75 1 2 3 T 51 3 4 5...
Page 52: ...52 4 T 5 T 3 6 4 T 5 1 2 3 T 4 3 T 5 T 6 T 52...
Page 53: ...53 100 1 2 1 5 1 5 Hoist Oil Supply On Hoist Lower 3 Oil Supply Jaw Open On Jaw Control On 53...
Page 54: ...54 4 1 1 4 5 100 100 Extend On 100 Retract 100 1 2 1 6 3 1 4 4 5 54 1 1...
Page 55: ...55 100 1 2 3 4 2 1 2 5 100 55 1 2 3 4 5 6 7 A B C D E A B A B A B C A B C A B C A B C D E...
Page 56: ...Notes 56...
Page 64: ...64 Notes 64...
Page 74: ...Notes 74...
Page 75: ...Notes 75...
Page 76: ...POWERFUL SOLUTIONS GLOBAL FORCE www enerpac com...