Installation sketch
When connecting the power cable between the outdoor unit and indoor unit, cables connected
to the terminal block in indoor unit must match these in outdoor unit.
For example, if the terminals and power cables are connected as
→
gree/yellow cable,
L
→
red cable
,
N
→
blue cable
,
S
→
black cable in indoor unit, the connections in the outdoor
unit should be in the same way.
Indoor unit
Extension cable for sensor
Sensor
Place all sensors in right positions
Sensor cable connection
E. Sensor cables
All temperature sensors are preinstalled in the unit, and the unit can be operated without any changes.
Still for different applications it is possible to move the sensors to the place you wish to have the units
temperature readings for the controller. For
example
if
the
unit
is
connected
to
a
buffer
tank
or
accumulating
water
tank
,
it
is
more
efficient
to
let
the
heat
pump
be
controlled
by
the
water
temperature
in
the
water
tank
.
1. Disconnect the sensor with the quick connector inside the indoor unit.
2. Insert the sensor cable from indoor PCB through cable gland on top of indoor unit.
3. Connect the sensor cable which stick out on top of indoor unit with extension cable for sensor.
4. Connect the other side of extension cable with the sensor.
5. Place the sensor in right position, according to your application, as shown in the pictures below.
6.Make sure to let water temperature sensors to have good contact by using cooling past in sensor
pockets, and insulate sensors located directly on water pipes.
A
Sensor cables
-26-
2.INSTALLATION