Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual
U. S. 16
Installation
c.
Set Pointers.
Hold dial securely with one
hand and move the pointers with the
other hand. Do not force the pointers past
any stops on the dial even though the dial
may be graduated beyond the stops.
i.
Limit.
Verify that the right hand
pointer is set at 200-degrees F. This
is the temperature at which contacts
should open to prevent your Furnace
from overheating. Never set the Limit
pointer higher than 200-degrees F, as
recommended by the Fan/Limit
Control manufacturer.
ii.
Fan
. Move the “Fan On” pointer so
that its straight edge indicates the
temperature at which the fan contacts
should close to start the blower. Move
the “Fan Off” pointer so that its
straight edge indicates the
temperature at which the fan contacts
should open to stop the blower.
Recommended “Fan On” setting is
145-degrees F. Recommended “Fan
Off” setting is 90-degrees F.
8.
Circulation Blower
.
a. Mount circulation blower on rear of
furnace using the four bolts supplied.
b. If you selected the optional Filter Box kit,
proceed to step 9. Otherwise, attach the
conduit to Control Box and connect wire
ends as detailed in
Appendix A: Wiring
Diagrams
.
Do not connect power to
your ENERGY KING Wood/Coal
Furnace until the installation is
complete.
9.
Cold Air Return & Optional Filter Box.
a. Determine whether your cold air return
will enter on the left or right side of the
furnace.
b. Assemble the optional filter box per
Appendix B: Filter Box Assembly
Schematic
.
c. Feed the conduit from your circulation
blower through the hole located on the
top of the filter box. Attach the conduit to
Control box and connect wire ends as
detailed in
Appendix A: Wiring Diagrams
.
Do not connect power to your
ENERGY KING Wood/Coal Furnace
until the installation is complete.
10.
Domestic Hot Water Tube (Optional).
a. Your optional domestic hot water tube
may have been installed at the factory. If
so, your plumber can connect your
domestic hot water supply per the
installation instructions provided by the
hot water tube manufacturer.
b. If your optional domestic hot water tube
was not factory-installed, please follow
the installation instructions provided by
the hot water tube manufacturer.
11.
Wiring. Do not connect power to your
ENERGY KING Wood/Coal Furnace until
the installation is complete.
Once you’ve completed the installation of
your ENERGY KING Wood/Coal Furnace,
you may connect your 110V power supply
to the left side of the control box. Wiring is
based on draft choice. Please see
Appendix A: Wiring Diagrams
.
Risk of electric shock.
Disconnect power at the service
panel or breaker box before
servicing the ENERGY KING
Wood/Coal Furnace.
Figure 10: Fan/limit Control Settings
Recommended “Fan Off” setting is 90 º F.
Recommended “Fan On” setting is 145º F.
Summary of Contents for 360EK
Page 2: ......
Page 4: ......
Page 8: ...Rev 03 12 14 ENERGY KING 360EK 365EK 480EK Wood Coal Furnace Owner s Manual U S 2 ...
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......