ENERGY KING™ Wood/Coal Boiler Owner’s Manual
U. S.
11
Installation
•
As Primary Boiler
Locate the ENERGY KING Wood/Coal
Boiler as close to the new or existing
chimney as possible. The ENERGY KING
heating appliance should be placed so that
you can easily complete operation and
maintenance procedures.
Locate the 24-V Wall Thermostat provided
with your ENERGY KING heating appliance
in the living area of the home. Your draft
system is controlled primarily by the wall
thermostat, so proper placement and
installation of the wall thermostat is crucial.
Strictly adhere to all requirements
pertaining to clearances to combustibles,
combustion air, venting system, draft
control, and thermostat installation.
•
As Add-On Boiler
The ENERGY KING Wood/Coal Boiler is
designed to be used in conjunction with a
listed gas- or oil-fired boiler, but not all
boilers will accept an add-on application.
Some small boilers may not be used in an
add-on installation.
Before installing your ENERGY KING
Wood/Coal Boiler, consult your heating
contractor and local, state and national
building codes and regulations to determine
if your existing hydronic heating system is
compatible with the ENERGY KING
Wood/Coal Boiler.
When using your ENERGY KING
Wood/Coal Boiler in an add-on application,
locate the ENERGY KING Wood/Coal
Boiler as close to the new or existing
chimney as possible, and as close to your
existing boiler as practical. However a
minimum clearance of 12-inches is required
between your existing boiler and your
ENERGY KING Wood/Coal Boiler.
Locate the 24-V Wall Thermostat provided
with your ENERGY KING heating appliance
in the living area of the home, near your
existing thermostat. Your draft system is
controlled primarily by the wall thermostat,
so proper placement and installation of the
wall thermostat is crucial.
Clearances to Combustibles
•
Sides:
The ENERGY KING Wood/Coal
Boiler must have clearances of 18 inches
from the sidewall of the ENERGY KING
Wood/Coal Boiler to combustibles.
•
Front:
Leave a minimum clearance of 48
inches in front of your ENERGY KING
heating appliance. This is for safe, easy
loading and cleaning of your ENERGY
KING heating appliance.
•
Rear:
The minimum clearance from the
rear of the ENERGY KING Wood/Coal
Boiler to combustibles is 20 inches.
•
Top:
The minimum clearance from the
top of the ENERGY KING Wood/Coal
Boiler to combustibles is 18 inches.
•
Stovepipe:
Stovepipe must have a
minimum of 18 inches to combustibles.
•
Additionally, when using your ENERGY
KING Wood/Coal Boiler as an add-on, a
12-inch minimum clearance is required
between the ENERGY KING Wood/Coal
Boiler and your existing boiler.
Figure 2: Clearances to Combustibles
Summary of Contents for 35EKB
Page 2: ......
Page 4: ......
Page 43: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 37 Appendix A Wiring Diagram...
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......