background image

 

Ascent Oil 

– August 2019 

 

36 

 

LIMITED WARRANTY  

(Continued from Previous Page) 

 

7.  Systems installed with chimneyless, through the wall venting option may have less than complete or poor 

combustion which may cause sooty fumes, odors or gradual discoloration of the area near the vent (exhaust) 
outlet.  Poor combustion is generally the result of a burner being out of adjustment for a number of reasons, 
including but not limited to fuel condition and combustion air supply.  Energy Kinetics does not guarantee nor 
warranty that all times the exhaust contents will be without a trace of soot or odor for reasons described 
above.  Periodic cleaning and repainting of the area around the vent hood may be required if the appearance 
is objectionable in the view of the end user.  Such cleaning or repainting is not the responsibility of the 
service company, installer or manufacturer. 

 

LIFETIME WARRANTY TRANSFER 

By completion of the Lifetime Warranty Transfer Agreement, the original owner may transfer the warranty to a 

new owner by payment of a $75 registration fee. 

 

WARRANTY SERVICE 

For prompt warranty service, notify the installer who in turn will notify Energy Kinetics that the purchaser believes 

there is a defect in material or workmanship covered by this warranty statement. 

If within 30 days of the discovery, this action does not produce a prompt response, notify Energy Kinetics, Inc. 51 

Molasses Hill Road, Lebanon, NJ 08833, in writing with details to support the warranty claim. 

The End User is required to make available for inspection by Energy Kinetics or its representative, the parts 

claimed to be defective and, if requested by Energy Kinetics, to ship said parts prepaid to Energy Kinetics at the 
above address for inspection or repair.  In addition, the homeowner agrees to make all reasonable efforts to settle 
any disagreement arising in connection with this claim before resorting to legal remedies in courts.  If you have any 
questions about the coverage of this warranty, contact Energy Kinetics at the above address.  

 

 

 

Lifetime Warranty Transfer Agreement 

(I/We), the undersigned, as the original purchaser of the 

Model EK1T or Model EK1T+ 

home heating system, 

submitted the 

Warranty Registration

 within three (3) months of installation of (my/our) 

Model EK1T or Model EK1T+

 

to Energy Kinetics, Inc., and (I/we) hereby transfer our Lifetime Limited Warranty to the new owner(s) of the home 
located as noted below and understand a thirty (30) day waiting period applies.  Warranty coverage begins on the 
date of original installation.

 

  

 

Model EK1T or Model EK1T+

Serial Number: 

_         Date of Original Installation: 

 

 

Name of original purchaser of

 Model EK1T or Model EK1T+

 

 

 

Print or Type full Name(s) 

 

Located at this street address: 

 

 

 

City: 

 

 

State: 

 

 

Zip:

  

 

 

TRANSFER TITLE of ENERGY KINETICS’ WARRANTY TO:  

 

 

Print or Type full Name(s) 

New Owner(s) of the 

Model EK1T or Model EK1T+

 located at the address noted above.  Title to be effective, 

 

 

and continues uninterrupted coverage as is left on the original warranty. 

        

Enter Date  

 

       of Title Transfer 

 

(Example: If the original owner has used 9 years, 3 months and 10 days of the warranty, the new homeowner 
warranty transfer begins at 9 years, 3 months and 11 days and continues to the end of the warranty as described on 
the back of this agreement or until the new homeowner sells the residence). 

 

Enclosed is a check for $75.00 to register and maintain the warranty as described on the back of this Warranty 
Transfer Agreement to the new homeowner named above.  Please make check payable to Energy Kinetics, Inc. 

 

Agreed to by the Original Homeowner: 

 

 

Accepted:

  

 

 

Original Homeowner Signature 

New Homeowner Signature 

 

*****************************************************

  

For Office Use Only

  ************************************************ 

 

Energy Kinetics, Inc. Received Transfer Information: 

 

  $75.00 Received 

 

 

Check No. 

 

 

 

Date Received and Registered 

 

Confirmation of Transfer mailed to New Homeowner: 

 

  By: 

 

 

 

Date 

Office Personnel

 

 

Summary of Contents for SYSTEM 2000 Ascent Combi

Page 1: ...gykinetics com INSTALLER HANG THIS INSTRUCTION MANUAL AND ACCESSORY INSTRUCTIONS VISIBLY NEXT TO THE BOILER USING THE SUPPLIED POUCH ASME certified by EKI Certificate plate is under the jacket on the...

Page 2: ...enings sized and located per boiler manual and applicable codes WARNING Have the burner boiler started up and serviced at least once annually by a qualified service technician Professional care is nec...

Page 3: ...ipment Daily inspect the space around the burner boiler to verify the area is clean and free of the materials listed above Monthly watch the operation of your burner boiler through an operating cycle...

Page 4: ...L BURNER MOUNTING 13 GENERAL ASSEMBLY 14 ZONE CONTROL 17 BOILER BYPASS CIRCULATOR 18 FILLING WITH WATER VENTING and PURGING 18 BOILER WATER TREATMENT 19 ANTI FREEZE 19 WINTERIZING 19 LINE VOLTAGE WIRI...

Page 5: ...tune up by a qualified service agency to maintain top efficiency and peak performance and to verify proper performance of all safety devices PERIODIC MAINTENANCE The Ascent Combi boiler requires mini...

Page 6: ...r spa and or pool heating systems Call Energy Kinetics to obtain piping and wiring instructions for applications such as hydronic heating radiant heating domestic hot water swimming pool heating multi...

Page 7: ...tion thereto should leak the resulting flow of water will not cause damage to the area in which it is installed A hot water storage tank should be installed in such a manner that if the storage tank o...

Page 8: ...ed around each other Water travels along one passageway from your home toward the center of the unit and heated gases travel from the unit center toward the vent This is a forced circulation counter f...

Page 9: ...ed or lost prior to installation LOCATION and CLEARANCE DANGER Provide clearance to combustible surfaces in accordance with all local and national codes Follow National Fire Protection Association Bul...

Page 10: ...stion An optional sealed air box Silent Burner Cover included in the Combi Plus model allows combustion air to be piped from outside the building Piping of outside air directly to the boiler is highly...

Page 11: ...the flue connector to allow scale and condensation to accumulate without blocking the flue pipe Do not block the flue opening by inserting the flue connecter too deeply into the chimney Best Practice...

Page 12: ...nting products as outlined in the supplemental manual and must not be vented with L Vent or any conventional chimney products FUEL SYSTEMS NOTICE Inspect and if needed replace oil lines according to l...

Page 13: ...the heat of combustion and then seals the air tube flange joint with a high grade retort cement NOTICE Oil burners for field installation or for field replacement should be installed according to burn...

Page 14: ...good practices The diagrams and locations presented in the manual are recommended Ascent Combi EK1T Ascent Plus Combi EK1T Air Vent and T P Gauge Power Venter Ascent Hydrostat 18 Plate Heat Exchanger...

Page 15: ...EXPANSION TANK LOCATION FEEDWATER CONNECTION EXPANSION TANK TO BE LOCATED IN RETURN PIPING ITEMS INSIDE PHANTOM BOX NOT INCLUDED WITH SYSTEM OPTIONAL TRIM KIT INCLUDES EXP TANK FEEDER PREVENTER OPTIO...

Page 16: ...inetics to obtain piping and wiring instructions for alternate applications such as hydronic heating radiant heating domestic hot water swimming pool heating multiple boilers injection loops etc Figur...

Page 17: ...he Ascent Hydrostat control to complete the call for heat ZONE CONTROL BY CIRCULATOR Zone control by circulators requires a circulator relay with end switch EK P N 10 0464 4 SR504 or equivalent or ind...

Page 18: ...the bypass circulator provides forced circulation to the plate heat exchanger to allow rapid and efficient heat transfer to the domestic water NOTICE Heat Only systems come from the factory with bypa...

Page 19: ...d antifreeze to obtain approximately a 30 by volume mixture of antifreeze in water Call Energy Kinetics for assistance in calculating how much anti freeze to add to system WINTERIZING NOTICE If the As...

Page 20: ...Ascent Oil August 2019 20 LINE VOLTAGE WIRING DIAGRAMS Figure 3A Combi All wiring installations in The United States must comply with the NEC and any local codes...

Page 21: ...ics to request alternate low voltage wiring diagrams to handle special situations such as air handler wiring heat pump wiring Wi Fi and power stealing thermostats or isolation relays for thermostats A...

Page 22: ...d and will remain hot for over 2 hours after preheating so after activated the water will be ready for an extended period of time Option 3 OP3 This option is a compromise between maximum efficiency an...

Page 23: ...boiler functionality To temporarily install an off the shelf Hydrostat 3250 on the EK1T or EK1T follow the standard wiring diagram with the following exceptions 1 Reinstall the flow switch to ZC and...

Page 24: ...determined The blocked intake switch can be disabled by removing the flex tubing on the Dilution Air Exhaust Fan inducer assembly that connects it to the pressure tap After removing the tube run the b...

Page 25: ...leed air from pump 3 On light off water temperature and stack temperature will start to rise A slight odor is common on initial light off as refractory and converter surfaces warm for the first time 4...

Page 26: ...ank 10 7 1 Although the Ascent Combi Boiler can operate without a trace of smoke above 14 CO2 the nominal gain in efficiency may not offset the potential of increased maintenance costs Note 1 For comb...

Page 27: ...Plus Combi flexible coupling clamps and condensate drain Step 4 Clean Boiler Remove stainless steel alloy combustion chamber using caution it may be hot Brush and vacuum the heat exchange surface if...

Page 28: ...y and check ignitor 4 Check Filter condition Replace annually and if vacuum exceeds 7 for single pipe systems 5 Check flexible oil line for leaks or corrosion Gently bend hose along its length to chec...

Page 29: ...xing valve up and down in temperature to ensure that it moves freely Set the mixing valve temperature feeding the domestic hot water fixtures to the desired temperature of approximately 120 F using mi...

Page 30: ...Hydrostat control to simulate a thermostat call c Restore power The burner should start shortly d At approximately 180 F the Ascent Hydrostat control should shut off burner e Turn off power and discon...

Page 31: ...eaning hoses to the drain valves at C location Attach the hose on the supply side of the EK1T s or EK1T s hot water system on hot water make up valve A near the flow switch to a submersible or pond pu...

Page 32: ...EZ1 10 0447 18 Plate Heat Exchanger ITEM EK1T DESCRIPTION ITEM EK1T PART NO DESCRIPTION PART NO A 10 0828 Combustion Chamber Stainless L 10 0830 Rear Insulation Board 2 B1 10 0825 Energy Converter As...

Page 33: ...Ascent Oil August 2019 33 NOTES...

Page 34: ...Ascent Oil August 2019 34...

Page 35: ...e of the trade list price of such pressure vessel at the time the warranty claim is made as determined in the following YEAR 1 st 11 th 12 th 13 th 14 th 15 th 16 th 17 th Percent of Trade list Price...

Page 36: ...to settle any disagreement arising in connection with this claim before resorting to legal remedies in courts If you have any questions about the coverage of this warranty contact Energy Kinetics at...

Reviews: