![ENERGY KINETICS EK1C Installation & Service Manual Download Page 4](http://html1.mh-extra.com/html/energy-kinetics/ek1c/ek1c_installation-and-service-manual_2410385004.webp)
Accel CS Boiler - Gas Heat - Eighth Edition – January, 2015
3
FOR YOUR SAFETY READ BEFORE OPERATING
A. This burner does not have a pilot. It is equipped with an ignition device which automatically
lights the burner.
DO NOT
try to light the burner by hand.
B. BEFORE OPERATING, smell all around the boiler area for gas. Be sure to smell next to the
floor because some gas is heavier than air and will settle on the floor. See below.
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electric switch; do not use any phone in your building
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
•
If you cannot reach your gas supplier, call the fire department.
C.
Use only your hand to turn the gas “shutoff” valve. Never use tools. If the handle will not turn
by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair
may result in a fire or explosion.
D. Do not use this boiler if any part has been under water. Immediately call a qualified service
technician to inspect the boiler and to replace any part of the control system and any gas
control, which has been under water.
OPERATING INSTRUCTIONS
1.
STOP!
Read the safety information above.
2. Set the thermostat(s) and aquastat(s) to their lowest setting.
3. Turn the service switch located on the front panel
“OFF”
.
4. This burner is equipped with an ignition device which automatically lights the burner. Do not try
to light the burner by hand.
5. Turn the external
manual gas valve
handle clockwise to the “
CLOSED”
position (valve
handle will be perpendicular to gas piping).
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas,
STOP!
Follow the safety information above. If you don’t smell gas, go to the next
step.
7. Turn
manual gas valve
handle counterclockwise to the “
OPEN” position (valve handle
will be parallel to gas piping)
.
8. Set thermostat(s) to desired setting.
9. Turn on all electric power to the burner and boiler.
10. If the burner/boiler will not operate, follow the instructions
“TO TURN OFF GAS TO THE
BURNER”
below and call your service technician or gas supplier.
TO TURN OFF GAS TO THE BURNER
1. Set thermostat(s) to their lowest setting.
2. Turn the service switch on the Accel CS front panel “
OFF”
.
3. Turn the external
manual gas valve
handle clockwise to the “
CLOSED”
position.
WARNING:
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
External manual
gas shutoff valve,
supplied by installer.
A typical ball valve is shown,
some models do not have a
handle, your installation may
vary.
Summary of Contents for EK1C
Page 60: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 59 DRAWINGS WIRING...
Page 61: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 60 DRAWINGS WIRING...
Page 62: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 61 DRAWINGS WIRING...
Page 63: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 62 DRAWINGS WIRING...
Page 64: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 63 DRAWINGS WIRING...
Page 65: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 64 DRAWINGS WIRING...
Page 66: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 65 DRAWINGS WIRING...
Page 71: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 70...
Page 72: ...Accel CS Boiler Gas Heat Eighth Edition January 2015 71 THIS IS A BLANK PAGE...