Wiring connection of Outdoor Unit for SAU24P1-A
Unscrew the screw, take off the control panel cover from the unit.
Connect the cable to their terminals according to their number.
Fix the cable to the terminal board with fastening piece.
Reinstall the cover with the screw.
The grounded wire connection:
1.loosen the grounded screw of electrical shelf.
2.Connect the grounded wire with the grounded screw then setscrew in the
mark formerly.
NOTE:
The connection mark should be agreed on for indoor unit and outdoor unit.
Don't reverse the power polarity.
The wrong connection lead to the malfunction of some electrical parts.
Must fix the screwnail of the firmly wire, then drag the wire lightly, confirmation
whether it's firmly.
Must changed if the wire slide, the self-drive screw can't used to the electric connection.
If there is a connector, connect it directly.
12000W
Connector
L1
L2
L3
N
Yellow/Green
L1
L2
L3
N
Yellow/Green
1
2
Cold wind Type
Terminal board for outdoor unit
Yellow
Green
Heat pump Type
1
4
5
2
Yellow
/Green
Terminal board for outdoor unit
Terminal board for outdoor unit
Terminal board for outdoor unit
Cover
Fastener for cable
connection
shelf
Grounded wire
Terminal board
Inter
connectio
n cord
More than 5mm
Connector
1
2
1
4
5
2
L1
L2
L3
N
L1
L2
L3
N
Technical Manual of
Energolux
Room Air Conditioner
16
Summary of Contents for SAP24P1-A
Page 1: ...SERVICE MANUAL Split system Cabinet Type R410a Designed in Switzerland...
Page 4: ...Technical Manual of Energolux Air Conditioner Outdoor Unit SAU24P1 A SAU48P1 A SAU60P1 A 4...
Page 30: ...Technical Manual of Energolux Air Conditioner Outdoor unit SAU24P1 A 30...
Page 32: ...Technical Manual of AUX Air Conditioner Outdoor unit SAU48 60P1 A 32...
Page 45: ...Technical Manual of Energolux Air Conditioner 8 2 Outdoor unit for 42K Cooling only 45...