Energic PlusPlus MVM User Manual Download Page 9

Battery charger MVM

USER'S MANUAL

 

 

5.    HOW TO USE THE CHARGER     

HOW TO CONNECT THE BATTERY

Check that the charger is switched OFF

;

Select the battery voltage by moving the selection plug to the proper connector; 

Connect the charger to the battery;

CHARGE OPERATION

Move the timer clockwise to start the charger.
Read immediately the output current  on the ammeter, to make sure that it's not too high, 
otherwise the output fuse of the charger will blow. 

 Attention:The operations described in this chapter are done by 

Energic Plus 

MVM 

chargers automatically.

 Attention: 

This   battery   charger   is   not   automatic,   therefore   if   it's   not   set  
properly the battery may be damaged.
It's necessary to survey the operation and keep the battery 
temperature   always   under   control   while   it's   connected   to   the 

charger.

END OF THE CHARGE

When the timer reaches the position zero, the charger switches off.
If it's necessary to interrupt the charge before the normal termination, it's necessary to switch 

of the charger by moving the timer manually to zero.

 Attention:

Before disconnecting the battery, make sure that the charger is off, to 
avoid dangerous sparks between connectors. 

- End of Manual - 

__________________________________________________________________________________________________________________________________________________

Code: OWM-MVM-261006

     

Page 9/9

Summary of Contents for MVM

Page 1: ...M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User s MANUAL ______________________________________________________________________________________________________________________________________________...

Page 2: ...mum input current A Maximum power consumption KVA Input frequency Voltage of the battery output voltage Maximum charge current output current RESPONSIBILITY DISCLAIMER The manufacturer of the MVM batt...

Page 3: ...ect single phase equipment to ONLY TWO WIRES of the 3 phase line DO NOT CONNECT the equipment grounding conductor to the third live wire of the 3 phase line as this makes the equipment frame electrica...

Page 4: ...prevent arcing and burning of the connector contacts be sure the charger is OFF before connecting or disconnecting the battery The ammeter should NOT indicate current flow MEDICAL AND FIRST AID TREAT...

Page 5: ...s set by the mechanical timer The output voltage can be selected between the four available values 12 24 36 48V by moving the selection plug to the required position The output current follows the Wa...

Page 6: ...og ammeter Plug and connectors for battery voltage selection No 2 Cables for battery connection No 1 Cable for main supply connection Inside the charger there are the following devices not available t...

Page 7: ...on To avoid electrical shock do not open the cabinet Refer servicing to qualified personnel only Attention Allow adequate air circulation to prevent internal heat buildup Do not place the unit near ma...

Page 8: ...he charge current by following these steps Disconnect the charger from main supply and battery Open the cabinet Find the plugs for input voltage setting Disconnect the wire A from the original plug Co...

Page 9: ...ry charger is not automatic therefore if it s not set properly the battery may be damaged It s necessary to survey the operation and keep the battery temperature always under control while it s connec...