Battery charger MVM

USER'S MANUAL

 

 

4. INSTALLATION OF THE CHARGER

Conditions of use: 

Operating temperature:

5°C to 45°C

Storage temperature:

-20°C to 60°C

Relative humidity:

less than 75%

 Caution:

The charger can be installed by qualified personnel only.

 

Attention:

Check that the unit’s maximum input power is available from your 
power supply. Check that the unit’s operating voltage is identical 
to your local power supply.

 Attention: 

To prevent fire or shock hazard, do not expose the unit to rain or 
moisture.
Do not use the unit in presence of flammable gas, because it can 
generate sparks.

 Caution: 

To avoid electrical shock, do not open the cabinet. Refer servicing 
to qualified personnel only. 

 Attention: 

Allow adequate air circulation to prevent internal heat buildup.
Do not place the unit near materials that may block the ventilation 
slots.

Do not install the unit near heat sources such as radiators or air 

ducts,   or   in   a   place   subject   to   direct   sunlight,   excessive 

dust,  mechanical vibration or shock.

CONNECTION OF THE CHARGER

Check the efficiency of earth circuitry;

Connect the charger to the mains using an adequate plug, with switch and fuses;

Use an adequate plug to connect the charger to the battery;

__________________________________________________________________________________________________________________________________________________

Code: OWM-MVM-261006

     

Page 7/9

Summary of Contents for MVM

Page 1: ...M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User s MANUAL ______________________________________________________________________________________________________________________________________________...

Page 2: ...mum input current A Maximum power consumption KVA Input frequency Voltage of the battery output voltage Maximum charge current output current RESPONSIBILITY DISCLAIMER The manufacturer of the MVM batt...

Page 3: ...ect single phase equipment to ONLY TWO WIRES of the 3 phase line DO NOT CONNECT the equipment grounding conductor to the third live wire of the 3 phase line as this makes the equipment frame electrica...

Page 4: ...prevent arcing and burning of the connector contacts be sure the charger is OFF before connecting or disconnecting the battery The ammeter should NOT indicate current flow MEDICAL AND FIRST AID TREAT...

Page 5: ...s set by the mechanical timer The output voltage can be selected between the four available values 12 24 36 48V by moving the selection plug to the required position The output current follows the Wa...

Page 6: ...og ammeter Plug and connectors for battery voltage selection No 2 Cables for battery connection No 1 Cable for main supply connection Inside the charger there are the following devices not available t...

Page 7: ...on To avoid electrical shock do not open the cabinet Refer servicing to qualified personnel only Attention Allow adequate air circulation to prevent internal heat buildup Do not place the unit near ma...

Page 8: ...he charge current by following these steps Disconnect the charger from main supply and battery Open the cabinet Find the plugs for input voltage setting Disconnect the wire A from the original plug Co...

Page 9: ...ry charger is not automatic therefore if it s not set properly the battery may be damaged It s necessary to survey the operation and keep the battery temperature always under control while it s connec...

Reviews: