Energic PlusPlus MVM User Manual Download Page 5

Battery charger MVM

USER'S MANUAL

 

 

3.    DESCRIPTION OF THE CHARGER

The 

Energic Plus MVM

 battery chargers have been designed to charge Pb batteries. 

These units can convert the AC main supply in a DC output at the correct voltage, in order to 
charge the battery cells.

The time of charge is set by the mechanical timer.

The   output   voltage   can   be   selected   between   the   four   available   values   (12-24-36-48V)   by 
moving the selection plug to the required position.

The output current follows the Wa curve, with these initial values.

SELECTED VOLTAGE

INITIAL CURRENT 

12 V

50 A

24 V

50 A

36 V

35 A

48 V

30 A

__________________________________________________________________________________________________________________________________________________

Code: OWM-MVM-261006

     

Page 5/9

Summary of Contents for MVM

Page 1: ...M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User s MANUAL ______________________________________________________________________________________________________________________________________________...

Page 2: ...mum input current A Maximum power consumption KVA Input frequency Voltage of the battery output voltage Maximum charge current output current RESPONSIBILITY DISCLAIMER The manufacturer of the MVM batt...

Page 3: ...ect single phase equipment to ONLY TWO WIRES of the 3 phase line DO NOT CONNECT the equipment grounding conductor to the third live wire of the 3 phase line as this makes the equipment frame electrica...

Page 4: ...prevent arcing and burning of the connector contacts be sure the charger is OFF before connecting or disconnecting the battery The ammeter should NOT indicate current flow MEDICAL AND FIRST AID TREAT...

Page 5: ...s set by the mechanical timer The output voltage can be selected between the four available values 12 24 36 48V by moving the selection plug to the required position The output current follows the Wa...

Page 6: ...og ammeter Plug and connectors for battery voltage selection No 2 Cables for battery connection No 1 Cable for main supply connection Inside the charger there are the following devices not available t...

Page 7: ...on To avoid electrical shock do not open the cabinet Refer servicing to qualified personnel only Attention Allow adequate air circulation to prevent internal heat buildup Do not place the unit near ma...

Page 8: ...he charge current by following these steps Disconnect the charger from main supply and battery Open the cabinet Find the plugs for input voltage setting Disconnect the wire A from the original plug Co...

Page 9: ...ry charger is not automatic therefore if it s not set properly the battery may be damaged It s necessary to survey the operation and keep the battery temperature always under control while it s connec...