background image

 

 

41 

EG-PMS 

PROGRAMMABLE USB SURGE PROTECTOR 

All brands and logos are registered trademarks of their respective owners 

To remove the network device, select it and click the 

Remove

 button 

(see Figure #20 above)

. You can select multiple network devices using 

Ctrl

 and 

Shift

 keys. You can also remove all network devices by clicking 

the 

Clear

 button 

 

HINT:

 Use the popup menu which is available with the right mouse 

button click over the table.  

 
5.3. Managing device beeper and timer 

 
EG-PMS  produces  quite  a  few  audible  signals  (see  Section  2.3 

above). If these signals are not desirable then set the option 

Disable device 

beeper

 in the 

Advanced features

 window (see Figure #17 above).  

 
Another useful option available from the 

Advanced features

 window 

(see Figure #17 above) is the tuning of the device timer. Synchronization of 
the  device  timer  with  the  managing  PC  timer  is  available  by  using 

Sync

 

button from the 

Time schedule

 window (see Figure #6 above). If the device 

timer has a certain daily error it can be corrected using this tuning option. 

 

Push  Device  timer  tuning  button  to  access  the 

Device  time  tuning

 

window (see Figure #23 below) 

Summary of Contents for EG-PMS

Page 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА EG PMS PROGRAMMABLE USB SURGE PROTECTOR ...

Page 2: ...brands and logos are registered trademarks of their respective owners PROGRAMMABLE SURGE PROTECTOR PROGRAMMIERBARE STECKDOSENLEISTE PROGRAMMEERBARE STEKKERDOOS PARASURTENSEUR PROGRAMMABLE ПРОГРАММИРУЕМЫЙ СЕТЕВОЙ ФИЛЬТР ПРОГРАМОВАНИЙ СЕТЕВОЙ ФІЛЬТР ...

Page 3: ...trols of EG PMS 8 2 1 Side panel 9 2 2 Indicators 10 2 3 Audible signals 10 3 Installation 11 3 1 Getting started 11 3 2 Power Manager installation 13 4 Power Manager software 13 4 1 Managing EG PMS 13 4 2 Setting up the hardware schedule 18 4 3 Setting up the software schedule 23 4 4 Setting up application events 27 5 Power Manager advanced features 34 5 1 Processing the alarms 35 5 2 Managing EG...

Page 4: ...tched on off by a timer schedule by user or different events It is also possible to pre program the unit event timer schedule hardware schedule and then disconnect EG PMS from the managing computer The device can be used as an advanced standby killer 1 1 Features The main rocker switch enables switching all the sockets on and off In addition to it every manageable socket can be switched on and off...

Page 5: ...ower Manager software to react whenever a certain event occurs Windows or other programs start up shutdown simple typical applications could be switch my scanner on when I want to scan or switch my printer off whenever I exit Windows Real time Voltage monitor provides information about the actual status of each manageable socket on or off This information can be further utilized in various ways e ...

Page 6: ...endent hardware schedule events 16 per socket Time interval between the events from 1 minute to 180 days Timer accuracy no more than 2 seconds error per day providing power is always present Otherwise there can be an additional up to 2 seconds error per each power off Working temperature range from 10 to 40 C Dimensions 378 x 98 x 55 mm Net weight 1 0 kg 1 3 Hardware requirements Computer running ...

Page 7: ...AMMABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners 1 4 Package contents The package contains EG PMS User manual USB cable CD with Power Manager software for Windows ...

Page 8: ...ive owners 2 Indicators and controls of EG PMS Figure 1 Main rocker switch Z Indicator Socket 3 Silence button to suppress beeps Indicator POWER Non manageable socket Indicator Socket 4 Indicator Socket 2 Indicator Socket 1 Non manageable socket Socket 4 Socket 3 Socket 2 Socket 1 USB Connector Side panel ...

Page 9: ...9 EG PMS PROGRAMMABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners 2 1 Side panel Figure 2 Circuit breaker Power cord ...

Page 10: ...als Long beep will be heard after EG PMS is successfully connected to the computer USB port after the self test Short beep will be heard by switching the manageable sockets on and off Continuous beeps hardware event schedule is lost for example if the power supply was cut for a long time These beeps can be stopped by pressing the Silence button see Figure 1 above Alarm beep will be heard if the ma...

Page 11: ... first and then to the USB socket of the manageable computer or vice versa EG PMS can now be switched on and off by means of the Main rocker switch Z Two the first and the last sockets of EG PMS are marked with the symbol These two sockets are switched on and off by means of the Main rocker switch Z and cannot be managed by the computer so they are called non manageable sockets in this manual If E...

Page 12: ...ure 1 above is turned off then the manageable sockets cannot be switched on by either Power manager software or the hardware schedule As soon as you turn the Main rocker switch Z on then the Power manager software or the hardware schedule will be able to turn the manageable sockets on and off To protect the connected devices from possible high current and short circuit EG PMS is equipped with the ...

Page 13: ...n CD ROM drive in the My Computer window and launch SETUP EXE from the CD Follow instructions of the installation software 4 Power Manager software The Power Manager software is designed to support not only EG PMS but also other products of Energenie family After a successful installation a socket icon will appear in your system tray 4 1 Managing EG PMS Double click on the socket icon in the syste...

Page 14: ...EG PMS PROGRAMMABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 3 You will get then the window of the main control panel shown on the Figure 4 below ...

Page 15: ...ademarks of their respective owners Figure 4 Double click over each socket will switch it on and off green color means the socket is switched off red color means the socket is switched on Click the Settings button for each socket to access the Settings dialog box see Figure 5 below ...

Page 16: ...OGRAMMABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 5 You can choose a different device and another socket from the Device and Socket drop down list boxes ...

Page 17: ...can choose the icon from drop down list box Such icon is a fast way to switch the device connected to the socket on off or check the device status You can also assign a hot key to switch the socket on off Check the Switch ON and Switch OFF checkboxes and specify the hot keys To switch the socket on off on Windows startup wake up check the On Windows startup checkbox and choose the required action ...

Page 18: ... registered trademarks of their respective owners 4 2 Setting up the hardware schedule Using the Hardware schedule button available from the Settings window you can create the hardware timer schedule see Figure 6 below To add a new record click the Add button Figure 6 ...

Page 19: ...s of their respective owners The window Add entry will appear see Figure 7 below In the dialog box specify the required time and the action Figure 7 To edit the record select it and click the Edit button or just double click on the entry The window Edit entry will appear see Figure 8 below ...

Page 20: ...ton see Figure 6 above You can select multiple entries using Ctrl and Shift keys You can also remove all entries from the schedule by clicking the Clear button see Figure 6 above To repeat your event for example if you want to perform the same events every day use the Loop button see Figure 6 above and specify the loop time period in the Edit loop period window see Figure 9 below ...

Page 21: ... incorrect entries these will be highlighted and an error message will appear Click the Apply button again after correcting all the errors Use Sync button see Figure 6 above to synchronize device timer with PC clock Note that after synchronization past entries will be removed from the schedule HINT Use the popup menu see Figure 6 above which can be activated by the right mouse button click over th...

Page 22: ... 215 days Loop period can not exceed 180 days NOTE If the device is powered off the hardware schedule is still in the device memory and will be resumed when the power supply is restored However the whole schedule will be then delayed with the power cutoff time EG PMS will then start beeping indicating the hardware schedule problem Press Silence button once to turn the beeps off if you don t care a...

Page 23: ...pective owners 4 3 Setting up the software schedule Using the Software schedule button available from the Settings window you can create the software timer schedule see Figure 10 below NOTE the software timer schedule will only be executed if the managing computer is on and the Power Manager is launched ...

Page 24: ...S PROGRAMMABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 10 To add a new task click the Add button The Add task window will appear see Figure 11 below ...

Page 25: ... and or Switch OFF time checkboxes and specify the time to switch the socked on and or off If you want the same event to be performed periodically check Perform task every checkbox and specify the time interval You can also add remarks about the task in the Comment field To disable the task uncheck the Enabled checkbox and to enable the task again re check the checkbox ...

Page 26: ... All brands and logos are registered trademarks of their respective owners To edit the task select it see Figure 10 above and click the Edit button or just double click on the task The Edit task window will appear see Figure 12 below Figure 12 ...

Page 27: ...ch can be activated by the right mouse button click over the table see Figure 10 above 4 4 Setting up application events Using the Application events window you can specify the socket events when a certain application is launched or closed down You can also associate switching the sockets off or on with placement and removal of particular files in certain folders To use this feature push Applicati...

Page 28: ...BLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 13 To add a new program event click the Add app button The Add program event dialog will appear see Figure 14 below ...

Page 29: ...ective owners Figure 14 Specify the application title and path to it using the Browse button or typing it manually in the Title and Path name fields If you use the Browse button you can also select a shortcut to the application In this case the application title and path name will be taken automatically ...

Page 30: ...E The On run event will take place when the first window of the selected application is opened The On exit event will take place when the last window of the application is closed HINT Your device is an advanced standby killer Using this feature you can for example switch your scanner on off whenever Photoshop is started closed To add a new file event click the Add folder button see Figure 13 above...

Page 31: ...lly in the Path name field Specify the File name mask using wildcard characters Check then On placing and or On removal checkboxes and select the event and delay NOTE The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder The On removal event will take place when the last file matching the specified file name mask is remov...

Page 32: ...r to switch your printer on whenever you start printing and to switch it off again whenever you are ready with printing HINT If you have several printers connected to the same computer we suggest moving default spool directory of each printer to a separate location To edit the event select it and click the Edit button or just double click on the event see Figure 13 above The Edit file event window...

Page 33: ...ve owners Figure 16 To remove the event select it and click the Remove button see Figure 13 above You can select multiple events using Ctrl and Shift keys You can also remove all events by clicking the Clear button HINT Use the popup menu which can be activated by the right mouse button click over the table ...

Page 34: ...wners 5 Power Manager advanced features The following information is for advanced users which wish to have full access to the advanced features of EG PMS Click the Advanced features button available from the Settings window see section 4 1 above The following window will then appear see Figure 17 below Figure 17 ...

Page 35: ...lled a Voltage alarm The Voltage alarm can for example be caused by a blackout and will be resolved after power returns The Voltage alarm can also be triggered if for any reason a switching task could not be carried out switching malfunction Voltage alarms are accompanied with beeps unless Disable device beeper option is activated The default action by an alarm is to record this event into a log f...

Page 36: ...e Browse button to select the desired program to be launched whenever a voltage alarm is triggered Check the When alarm goes off checkbox then click the Browse button to select the desired program to be launched after the alarm status see above is resolved 5 2 Setting up network devices You can declare EG PMS as a shared device on your server and let the other users access it via the server To mak...

Page 37: ...able the network access to the device via this PC To prevent unauthorized access to the device enter the access password in the field Password NOTE The port 6100 should be open Contact your LAN administrator for further details To be able to use this shared EG PMS on a client PC choose Shared devices from the Main menu see Figure 3 above You will get the following window see Figure 20 below ...

Page 38: ...ABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 20 To add a new remote device press the Add button You will see the window Add network device see Figure 21 below ...

Page 39: ...hich is connected to EG PMS in the field Hostname Enter the name of the target EG PMS in the field Device name Enter access password in the field Password To disconnect from the device uncheck the option Enable set this option on again to regain the access To locate the shared device in your local network click the button Find A dialog box Find network device will ...

Page 40: ...their respective owners appear Choose the proper server and then the device and click OK button To edit the network device select it and click the Edit button or just double click on the network device see Figure 20 above The Edit network device window will appear see Figure 22 below Figure 22 ...

Page 41: ...er and timer EG PMS produces quite a few audible signals see Section 2 3 above If these signals are not desirable then set the option Disable device beeper in the Advanced features window see Figure 17 above Another useful option available from the Advanced features window see Figure 17 above is the tuning of the device timer Synchronization of the device timer with the managing PC timer is availa...

Page 42: ...wners Figure 23 Enter the correction value in seconds which will be applied every 24 hours and push OK button 5 4 Managing EG PMS via your own software To let you switch the sockets from your own applications the following command line interface syntax is supported pm exe on off device name socket name Examples ...

Page 43: ...ected devices the following information will then be provided and placed into Info ini file in the Power Manager folder DeviceName the user specified device name Socket name where is replaced by a certain socket number the user specified socket name Socket SwitchState where is replaced by a certain socket number TRUE when the socket is switched on FALSE when the socket is switched off Socket Volta...

Page 44: ...ABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners NOTE Each use of this command line option totally overrides the data in Info ini file NOTE Power Manager should be active ...

Page 45: ...rocker switch and indicators are not lit There is no power supply to the EG PMS Please make sure the EG PMS is connected to the power supply and the rocker switch is switched on Software reports Device I O request error after switching Check the grounding of EG PMS If inductive load like florescent lamps or motors are connected to EG PMS it is recommended to use an extra USB hub to connect EG PMS ...

Page 46: ...46 EG PMS PROGRAMMABLE USB SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners ...

Page 47: ...ronikgeräten Richtlijnen m b t afvalverwerking Batterijen en accu s dienen als klein chemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten zie www afvalgids nl U dient ervoor te zorgen dat de batterijen accu s leeg zijn en dus geen stroom meer kunnen leveren Let op de batterijen accu s dienen onbeschadigd ingeleverd te worden Gooi dit product niet weg in uw vuilnisbak Dit kan zowe...

Page 48: ...ays be calculated on the basis of the current market value of the defective products Die Garantie beträgt 36 Monate ab Verkaufsdatum an den Endverbraucher Das Kaufdatum und der Gerätetyp sind durch eine maschinell erstellte Kaufquittung zu belegen Bitte bewahren Sie Ihren Kaufbeleg daher für die Dauer der Garantie auf da er Voraussetzung für eine eventuelle Reklamation ist Innerhalb der Garantieze...

Page 49: ... Le talon de garantie doit énumérer clairement la date d achat et le type d appareil Conservez le reçu d achat pendant toute la durée de la garantie car elle est nécessaire pour toute réclamation Au cours de la période de garantie tous les défauts doivent être remplacé aux frais du fabricant soit par la réparation ou la remplacement de la pièce défectueuse ou l ensemble du produit Les travaux effe...

Page 50: ..._____ 20____ года Фирма продавец _________________________________ Адрес и телефон фирмы продавца ________________________________________________ М П С условиями гарантии ознакомлен и согласен Продавец _____________ Покупатель _____________ 1 Гарантійне обслуговування надається протягом терміну гарантії при наявності Гарантійного талону заповненого належним чином та виробу в повній комплектації 2...

Reviews: