The new event time should be in the future
There can not be a duplicate entry
The total quantity of events can not exceed 16 per socket
The total quantity of events also depends on the total execution
period of the schedule
The interval between the present and the last entry can not exceed
180 days
Without loop the total execution period of the schedule can not
exceed 215 days
Loop period can not exceed 180 days
NOTE:
The hardware schedule keeps running even when the device
is powered off. However it is recommended not to power off the device
for extended periods, because the built-in battery has a limited lifespan. If
the battery dies the schedule will be completely cleared. The total lifetime
of the battery is no less than 2 years if the device is powered off, and no
less than 5 years if the device is powered on.
If the hardware schedule has been set as set in the Power Manager
software, it executes and is displayed according to computer’s clock, not
EG-PMS-LAN’s clock. To avoid this mismatch, before setting the
schedule in software, make sure, that time on computer matches the time
on EG-PMS-LAN.