Troubleshooting 

 

 

 

 

The below statements are listed as troubleshooting guidelines. Further information is available 
through Energenics support. 

 

Q: What should I do if the unit will not turn on? 

A: Verify there is power to the system 
A:  Verify the display is reads correctly 
A:  Verify the Emergency Stop is not engaged 

 

 

Q:  Why does the unit turn off when I enter the room? 

A:  Safety features turn off lamps based on detection by the PIR sensor. 

 

 

Q: My system will turn on, but the lamps will not come on. 

A:  Verify the start cycle button is pressed 
A:  Inspect the lamp for age or physical failure 
A:  Contact Energenics Support for further information 

 

 

Q: My system is running fine, how do I verify the lamp output is correct? 

A:  The system has a status screen at the end of the cycle 
A:  Faults will indicate if the system is not performing correctly 

 

 

Q: The touchscreen has presented a flashing “Service Machine” icon. 

What does this mean? 

A: Every 8 running hours it is recommended that lamps be wiped 

down with isopropyl or rubbing alcohol. This will remove any 
debris that may have accumulated on the lamp. Once cleaned, 
you can reset this message by pressing USER SETTINGS 
button followed by RESET SERVICE LIGHT 

Summary of Contents for UV MAX Low Profile

Page 1: ...System Table of Contents Page 1 Energenics UV MAX Page 2 Advisories Purpose Contents Page 3 UV MAX Safe Operation Procedure Page 4 Safety Guidelines Page 5 System Description Page 6 System Delivery P...

Page 2: ...2...

Page 3: ...enter Contents This manual will serve as your reference guide for installation operation and service of your UV MAX system Reference to all parts warranty and support are included This manual covers t...

Page 4: ...t the end of this manual 4 Connect UV MAX to 120vac plugreceptacle 5 Press start on UV MAX control and exit treatment area 6 Adhere to recommended safety precautions to avoid potential injury Safety 1...

Page 5: ...protection UV C safety glasses designed to filter UV C and those of the wrap around type are recommended Safety glasses should be made of any material other than Quartz or Teflon OSHA Guidelines for U...

Page 6: ...source The system design provides the optimum in o UV dosage output to footprintserved o Rugged design build o Ease of use controls o User safety protection INDUSTRIAL STRENGTH FRAME AND STRUCTURE COR...

Page 7: ...ollowing procedure 1 Unpack your new system and stand upright 2 Inspect fully for damage If damage present contact Energenics prior to use 800 944 1711 3 Verify secure lamp installation 4 Plug in syst...

Page 8: ...Cycle state 4 Turn on system 5 Evacuate space Audio and Visual Indicators 1 Audio Alarm a Once Started LONG warning beeps increasing in frequency b During Process SHORT stroke beeps c Process Complete...

Page 9: ...Lamps shall be clean c System frame shall be in good condition d Display of system shall be clean 2 Plug in system power cord 3 Ensure all personnel are out oftreatment area 4 Operate system a Press S...

Page 10: ...LE TIMER screen is displayed and may be used to modify system variables as follows Countdown Timer control for time delay from when Start Cycle button is pressed to when system lamps come on Cycle Tim...

Page 11: ...en 2 Release Emergency Stop by pulling up on the red knob 3 Select HOME button to return to main screen 4 Press START CYCLE to resume normal operation of system System Faults Should cycle deactivation...

Page 12: ...recommended to test system performance using an ATPmeter Bi Annual 1 Inspect the system interior and exterior lamp for clean conditions 2 Clean as needed 3 It is recommended to test system performanc...

Page 13: ...Verify the start cycle button is pressed A Inspect the lamp for age or physicalfailure A Contact Energenics Support for further information Q My system is running fine how do I verify the lamp output...

Page 14: ...much cooler part of the protected area That portion of the chip is now much warmer than when the intruder wasn t there As the intruder moves so does the hot spot on the surface of the chip This moving...

Page 15: ...about 330 nm UV A The transparency is quite high so almost all UV A light will pass through glass Below 330 nm UV B and UV C almost 100 is blocked by normal glass Q Can I use an ATP Meter with the UV...

Reviews: