background image

System Description 

 

 

 
 

The UV-MAX ULTRA is designed for maximum disinfection through the 
shortest exposure time. More UV-C wattage allows shorter surface 
exposure times. Exposure times vary based on furthest distance from the 
UV-C source. The system design provides the optimum in: 

 

 

o

  UV dosage output to footprint served 

 

o

  Rugged design build 

 

o

  Ease of use controls 

 

o

  User safety protection 

 
 
 
 
 

 

INDUSTRIAL STRENGTH 

FRAME AND STRUCTURE 

 
 

CORROSION PROOF 

CONSTRUCTION 

 
 

6” INDUSTRIAL CASTERS 

 
 

HIGH OUTPUT PRE-HEAT 

LAMPS FOR LONG RUN 

TIME LENGTH 

 

ROOM SENSING 

TECHNOLOGY 

 

PIR SENSOR DETECTION 

SAFETY SHUTOFF

 

 
 

INDIVIDUAL LAMP 

FAILURE/MONITOR 

INDICATOR 

LED’S 

 
 

EMERGENCY STOP 

BUTTON 

 
 

BUILT TO IP56 WATER 

AND DUST STANDARDS 

 

SELECTABLE TARGET 

PATHOGEN 

Summary of Contents for MAX-ASSURE UV-MAX ULTRA

Page 1: ...081 Installation Operations Manual UV MAX ULTRA Mobile Surface Disinfection Unit Table of Contents 1 Advisories Purpose Contents 2 UV MAX Safe Operation Procedure 3 Safety Guidelines 4 System Descript...

Page 2: ...center Contents This manual will serve as your reference guide for installation operation and service of your UV MAX system This manual covers the system equipment products listed below o UV MAX ULTR...

Page 3: ...to recommended safety precautions to avoid potential injury Safety 1 You should never look directly at a UV lamp inoperation without wearing approved safety glasses Safety glasses should be made of a...

Page 4: ...exposed skin and appropriate eye protection Polycarbonate safety glasses designed to filter UV and those of the wrap around type are recommended OSHA Guidelines for Ultraviolet Exposure OSHA provides...

Page 5: ...the optimum in o UV dosage output to footprint served o Rugged design build o Ease of use controls o User safety protection INDUSTRIAL STRENGTH FRAME AND STRUCTURE CORROSION PROOF CONSTRUCTION 6 INDUS...

Page 6: ...he following procedure 1 Unpack your new system and stand upright 2 Inspect fully for damage If damage present contact MaxAssure Inc prior to use 239 643 2778 3 Verify secure lamp installation 4 Plug...

Page 7: ...Start Cycle 5 Evacuate space Audio and Visual Indicators 1 Audio Alarm There is no audible alarm for countdown or run cycle on the UV MAX ULTRA as not to interfere with medical facility monitoring eq...

Page 8: ...e to the system b Lamps shall be clean c System frame shall be in good condition d Display of system shall be clean 2 Plug in system power cord 3 Ensure all personnel are out of treatment area 4 Opera...

Page 9: ...ings and choosing Operation Mode Countdown Timer Customizing 1 From Start Cycle home screen press User Settings 2 The User Settings screen is displayed with Countdown Timer Adjustment arrows available...

Page 10: ...wall This screen is for observation only a Each laser will measure up to a 16 radius for a total of 32 forward and backward and 32 side to side b The machine will always calculate run time based on th...

Page 11: ...by pulling up on the red knob 3 Press Cycle Status to see treatment time remaining 4 Select Home button to return to main screen 5 Press Start Cycle to resume normal operation of system PIR Sensor Cyc...

Page 12: ...urn to main screen 4 Press START CYCLE to resume normal system operation Service Indicators The Service alert will illuminate every 8 run hours as a clean lamps notification or when lamps need replace...

Page 13: ...rvice button on Home screen b Lamp Replacement indicators will be illuminated in Red c Replace lamps as indicated d Press Factory Settings button e Enter Passcode 1470 and press enter f Press Reset Se...

Page 14: ...d to test system performance using an ATPmeter Bi Annual 1 Inspect the system interior and exterior lamp for clean conditions 2 Clean as needed 3 It is recommended to test system performance using an...

Page 15: ...Verify the start cycle button is pressed A Inspect the lamp for age or physicalfailure A Contact Energenics Support for further information Q My system is running fine how do I verify the lamp output...

Page 16: ...some much cooler part of the protected area That portion of the chip is now much warmer than when the intruder wasn t there As the intruder moves so does the hot spot on the surface of the chip This m...

Page 17: ...been applied to a surface Q What is the difference between bacteria and sporicidal modes A Your UV MAX Ultra is equipped with two modes of operation Bacterial and Sporicidal It is important for the us...

Reviews: