The UV-MAX ULTRA system is designed for repeat performance with consistent results. 
Based on system designs, minimal maintenance is required. Adherence to the following 
regular service of your system should provide years of disinfection. 

 

Each Duty Cycle 

 

1.  Inspect the system interior, exterior, and lamps for clean conditions 
2.  Clean as needed 

 

 

Monthly 

 

1.  Inspect the system interior, exterior, and lamps for clean conditions 
2.  Clean as needed 
3.  It is recommended to test system performance using an ATP meter 

 

 

Bi-Annual 

 

1.  Inspect the system interior and exterior lamp for clean conditions 
2.  Clean as needed 
3.  It is recommended to test system performance using an ATP meter 

 

 

“Service Machine” Message 

 

1. Every 8 running hours it is recommended that lamps be wiped down with clean cloth 

and isopropyl or rubbing alcohol. This will remove any debris that may have 
accumulated on the lamp. Once cleaned, you can reset this message by pressing 
USER SETTINGS button followed by RESET SERVICE LIGHT 

 

 

Note: The above steps are listed as the basic level of care, should the system be utilized 
in a heavy work environment, further care may be required. 

Summary of Contents for MAX-ASSURE UV-MAX ULTRA

Page 1: ...081 Installation Operations Manual UV MAX ULTRA Mobile Surface Disinfection Unit Table of Contents 1 Advisories Purpose Contents 2 UV MAX Safe Operation Procedure 3 Safety Guidelines 4 System Descript...

Page 2: ...center Contents This manual will serve as your reference guide for installation operation and service of your UV MAX system This manual covers the system equipment products listed below o UV MAX ULTR...

Page 3: ...to recommended safety precautions to avoid potential injury Safety 1 You should never look directly at a UV lamp inoperation without wearing approved safety glasses Safety glasses should be made of a...

Page 4: ...exposed skin and appropriate eye protection Polycarbonate safety glasses designed to filter UV and those of the wrap around type are recommended OSHA Guidelines for Ultraviolet Exposure OSHA provides...

Page 5: ...the optimum in o UV dosage output to footprint served o Rugged design build o Ease of use controls o User safety protection INDUSTRIAL STRENGTH FRAME AND STRUCTURE CORROSION PROOF CONSTRUCTION 6 INDUS...

Page 6: ...he following procedure 1 Unpack your new system and stand upright 2 Inspect fully for damage If damage present contact MaxAssure Inc prior to use 239 643 2778 3 Verify secure lamp installation 4 Plug...

Page 7: ...Start Cycle 5 Evacuate space Audio and Visual Indicators 1 Audio Alarm There is no audible alarm for countdown or run cycle on the UV MAX ULTRA as not to interfere with medical facility monitoring eq...

Page 8: ...e to the system b Lamps shall be clean c System frame shall be in good condition d Display of system shall be clean 2 Plug in system power cord 3 Ensure all personnel are out of treatment area 4 Opera...

Page 9: ...ings and choosing Operation Mode Countdown Timer Customizing 1 From Start Cycle home screen press User Settings 2 The User Settings screen is displayed with Countdown Timer Adjustment arrows available...

Page 10: ...wall This screen is for observation only a Each laser will measure up to a 16 radius for a total of 32 forward and backward and 32 side to side b The machine will always calculate run time based on th...

Page 11: ...by pulling up on the red knob 3 Press Cycle Status to see treatment time remaining 4 Select Home button to return to main screen 5 Press Start Cycle to resume normal operation of system PIR Sensor Cyc...

Page 12: ...urn to main screen 4 Press START CYCLE to resume normal system operation Service Indicators The Service alert will illuminate every 8 run hours as a clean lamps notification or when lamps need replace...

Page 13: ...rvice button on Home screen b Lamp Replacement indicators will be illuminated in Red c Replace lamps as indicated d Press Factory Settings button e Enter Passcode 1470 and press enter f Press Reset Se...

Page 14: ...d to test system performance using an ATPmeter Bi Annual 1 Inspect the system interior and exterior lamp for clean conditions 2 Clean as needed 3 It is recommended to test system performance using an...

Page 15: ...Verify the start cycle button is pressed A Inspect the lamp for age or physicalfailure A Contact Energenics Support for further information Q My system is running fine how do I verify the lamp output...

Page 16: ...some much cooler part of the protected area That portion of the chip is now much warmer than when the intruder wasn t there As the intruder moves so does the hot spot on the surface of the chip This m...

Page 17: ...been applied to a surface Q What is the difference between bacteria and sporicidal modes A Your UV MAX Ultra is equipped with two modes of operation Bacterial and Sporicidal It is important for the us...

Reviews: