Annex CC  

(informative)

Transportation, marking and storage for units that employ 

flammable refrigerants

The following information is provided for units that employ flammable refrigerants.

CC.1 Transport of equipment containing flammable refrigerants

Attention is drawn to the fact that additional transportation regulations may exist with 

respect to equipment containing flammable gas. The maximum number of pieces of 

equipment or the configuration of the equipment, permitted to be transported together 

will be determined by the applicable transport regulations.

CC.2 Marking of equipment using signs

Signs for similar appliances used in a work area generally are addressed by local 

regulations and give the minimum requirements for the provision of safety and/or 

health signs for a work location.

All required signs are to be maintained and employers should ensure that employees 

receive suitable and sufficient instruction and training on the meaning of appropriate 

safety signs and the actions that need to be taken in connection with these signs.

The effectiveness of signs should not be diminished by too many signs being placed 

together.

Any pictograms used should be as simple as possible and contain only essential 

details.

CC.3 Disposal of equipment using flammable refrigerants

See national regulations.

CC.4 Storage of equipment/appliances

The storage of equipment should be in accordance with the manufacturer’s instructions.

CC.5 Storage of packed (unsold) equipment

Storage package protection should be constructed such that mechanical damage to the

equipment inside the package will not cause a leak of the refrigerant charge.

The maximum number of pieces of equipment permitted to be stored together will be 

determined by local regulations.

Summary of Contents for ESC09WMA1A/ES5FX09A

Page 1: ...HAI VINO ENVIRONMENTAL TECHNOLOGY EQUIPMENT CO LTD please read this owner s manual carefully before operation and retain it for future reference Split Air Conditioner ESC09WMA1A ES5FX09A ESC12WMA2A ES...

Page 2: ...centrations it will not explode Refrigerants have high flammability Compared to common refrigerants R290 is a nonpolluting refrigerant with no harm to the ozonosphere The influence upon the greenhouse...

Page 3: ......

Page 4: ...for a work location All required signs are to be maintained and employers should ensure that employees receive suitable and sufficient instruction and training on the meaning of appropriate safety si...

Page 5: ...ion drawing 22 Installation prepare 24 Installation Installation of indoor unit 26 Installation of outdoor unit 30 Check after installation 34 Test operation 34 Attachment Configuration of connection...

Page 6: ...ay water on indoor unit It may cause electric shock or malfunction After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or f...

Page 7: ...rly grounded Incorrect grounding may cause electric shock Including an circuit break with suitable capacity please note the following table Air switch should be included magnet buckle and heating buck...

Page 8: ...self For the air conditioner with plug the plug should be reachable after finishing installation For the air conditioner without plug can circuit breaker must be installed in the line If you need to r...

Page 9: ...4 Parts Name Indoor unit Outdoor unit Note Actual product may be different from above graphics please refer to actual products...

Page 10: ...5 Parts Name Remote controller Display Temp indicator Power indicator ECO...

Page 11: ...ss button to set your required fan speed auto fan1 fan2 fan3 fan4 fan5 turbo stepless speed 5 Press or button to select fan blowing angle Note During operation point the remote control signal sender a...

Page 12: ...7 Remote Controller Health button ECO button I feel button I feel ECO...

Page 13: ...n button can adjust fan speed Press or button can adjust fan blowing angel When selecting cool mode air conditioner will operate under cooling mode Press or button to adjust setting temperature Press...

Page 14: ...this button can select up down swing angle Fan blow angle can be selected circularly as below Note When convert NO display into status if press this button after 2s swing status directly turns into NO...

Page 15: ...remote controller ti s the fixed position swing Left right swing louver of air conditioner will stop at the position as shown by the icon to swing There is no this function for some remote control No...

Page 16: ...me will increase or decrease 0 5 hour Hold or button the time will change quickly until reaching your required time Press Timer to confirm it The word HOUR ON HOUR OFF will stop blinking HOUR ON HOUR...

Page 17: ...ld plasma generator can effectively eliminate the bacteria and odor in the air 1 The H2O molecules are ionized 2 Neutral reaction between the positive ions and negative ions can eliminate bacterial an...

Page 18: ...on the low temperature heating function would be canceled In the low temperature heating mode Sleep and Low temperature heating function cannot start at the same time When low temperature heating mod...

Page 19: ...s dirty it is recommended to use a soft dry cloth or wet cloth to wipe it Note Do not remove the panel when cleaning it Clean filter 1 Open panel Pull out the panel to a certain angle as shown in the...

Page 20: ...son 1 Check whether air inlets and air outlets are blocked 2 Check whether air switch plug and socket are in good condition 3 Check whether filter is clean 4 Check whether drainage pipe is damaged Cle...

Page 21: ...please replace them No display when operating remote controller Check whether remote controller appears to be damaged If yes replace it Fluorescent lamp in room Take the remote controller close to ind...

Page 22: ...er range Adjust temperature to proper range Door and window are open Close door and window Odours are emitted Whether there s odour source such as furniture and cigarette etc Clean the filter Eliminat...

Page 23: ...information If there are other errors codes please contact qualified professionals for service Error code Name CL Filter clean remind H0 High exhaust temp protection H1 Overcapacity protection H2 Com...

Page 24: ...ed professionals for service Power cord is overheating or damaged Air conditioner gives off burning smell There s abnormal sound during operation Circuit break trips off frequently Indoor unit is leak...

Page 25: ...um room area The minimum room area is shown on the nameplate or following table a Leak test is a must after installation Maintenance notes Check whether the maintenance area or the room area meet the...

Page 26: ...s well ventilated Filling the refrigerant Use the refrigerant filling appliances specialized for R290 Make sure that different kinds of refrigerant won t contaminate with each other The refrigerant ta...

Page 27: ...22 Installation Drawing...

Page 28: ...e that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet co...

Page 29: ...cy devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circumstances 7 Th...

Page 30: ......

Page 31: ...T4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearly Step 3 Open piping hole 1 Choosing the...

Page 32: ...40 45 55 60 65 70 75 6 9 52 12 16 19 Step 5 Connect the pipe of indoor unit 1 2 3 4 Note The corresponding moment wrench is needed to connect the piping If other tools are used the pipe will be damag...

Page 33: ...clip connect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip 4 Put wiring cover back and then tighten th...

Page 34: ...pipe should be bound separate at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom Step 9 Hang the indoor unit 1 Put the bound pipes...

Page 35: ...should be installed at least 3cm above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6...

Page 36: ...nection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws 2 Fix the power connection wire and signal control wire with w...

Page 37: ...than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room Note The through wall height of drain hose shouldn t be...

Page 38: ...tatus for 1 2min to check if the pressure of piezometer remains in 0 1MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve compl...

Page 39: ...cause in sufficient cooling heating capacity Is heat insulation of pipeline sufficient It may cause condensation and water dripping Is water drained well It may cause condensation and water dripping...

Page 40: ...ing on the length of standard pipe add refrigerant according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter od liq...

Page 41: ...aper and prevent the burrs from getting into the pipe C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nu...

Page 42: ...ts appropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO fire extinguisher adjacent to the charging area No ignition sources No person carrying out work in relati...

Page 43: ...uate temporary solution shall be used This shall be reported to the owner of the equipment so all parties are advised Initial safety checks shall include That capacitors are discharged this shall be d...

Page 44: ...of aging or continual vibration from sources such as compressors or fans Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or...

Page 45: ...Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved then venting to atmosphere and finally pulling down to a vacuum...

Page 46: ...l times by a competent person Recovery equipment and cylinders conform to the appropriate standards d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that ref...

Page 47: ...refrigerants In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using...

Page 48: ...OOR UNIT kg 9 10 13 5 OUTDOOR UNIT 27 28 33 COPPER PIPE SIZE LIQUID mm in 6 1 4 6 1 4 6 1 4 GAS mm in 9 52 3 8 12 1 2 12 1 2 FUSE T3 15AH 250VAC Interconnection cord H07RN F 3G1 0 H07RN F 3G1 0 H07RN...

Page 49: ...Unit 3 B Building 4 Zhongdian high tech industrial park 7th technology road Tangjiawan town Xiangzhou District Zhuhai City China ZHUHAI VINO ENVIRONMENTAL TECHNOLOGY EQUIPMENT CO LTD...