2
8
Installation of Indoor unit
Step 6: Install drain hose
1
. Connect the drain hose to the outlet pipe of indoor unit.
2
. Bind the joint with tape.
●
Add insulating pipe in the indoor drain hose in order to prevent condensation.
●
The plastic expansion particles are not provided.
Step 7: Connect wire of indoor unit
1
. Open the panel, remove the screw on the wiring cover and then take down the cover.
2
. Make the power connection wire go through the cable-cross hole at the back of
indoor unit and then pull it out from the front side.
3. Remove the wire clip, connect the power connection wire to the wiring terminal
according
to
the
color;
tighten
the
screw
and
then
fix
the
power
connection
wire
with
wire
clip.
4. Put wiring cover back and then tighten the screw.
5. Close the hole.
Note:
●
All wires of indoor unit and outdoor unit should be connected be a professional.
●
If the length of power connection wire is insufficient, please contact the supplier for a
new one. Avoid extending the wire by yourself.
●
For the air conditioner with plug, the plug should be reachable after finishing
installation.
●
For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should be
more than 3mm.
outlet
pipe
drain
hose