6.0 PC Dialog
- 13 -
Operating Instructions Text Display
-
Save as:
The entire setup configuration can be saved in a file (extension: *.ntd).
-
Exit:
The program will be finished.
Configure PC interface:
Allows setting up the RS232 interface of the PC (COM1…COM4), to which the text
display is connected:
The TD interface is factory-configured as follows:
• ...
8 data bits
• ...
no parity
• ...
no handshake
• ...
Baud rate 57.6 KB .
Clicking “OK” accepts the changes and stores the new setup to
the PC local harddisk
Configure TD parameters:
-
Timer:
Allows the timer definition for text insertion and relay by receiving protocol data:
§
Text insert:
Defines the time the text
insertion of protocol data is active (in the
range from 1...255 seconds). By displaying
protocol data the timer starts and after time-
out all protocol data will be cleared.
§
Relay:
Defines the time the relay is in
energized state (assignment page 5).
The relay is triggerd by text insertion of the
protocol data and inactivated after the defined time. The maximum time is 99
seconds. By setting ‘00sec’ the relay is not triggerd by protocol data.
The current settings are shown in the main menu below on the right side.
NOTE: If the relay timer and data timer are active and the unit receives new
protocol data, the timer start anew. In this case the relay respectively data
insertion is longer active as defined.