background image

5) 

TIG PUNKT welding (spot welding) - 

the red

 

light should indicate 

 

 The following parameters can be set within given ranges: 

  Is[A] - welding current in amperes adjustable in the range of 5-200A with a 

resolution of 1A 

  Tn[s] - welding current rise time in seconds adjustable in the range 0.1-5s 

with a resolution of 0.1s 

  To[s] - welding current fall time in seconds adjustable in the range 0.1-20s 

with a resolution of 0.1s 

  Tpunkt[s]  -  duration  of  spot  welding  in  seconds  adjustable  in  the  range 

0.01 - 10s with a resolution of 0.01s 

  Tg[s] - time of gas flow after the arc extinction in seconds, adjustable in the 

range 1-25s with the resolution of 1s 

 

CONTACT IGNITION - LAMP (8) IS OFF 

 The  welding  process  is  initiated  by  pressing  (and  releasing)  a  control 

button  on  the  grip. When  the  button  is  pressed  the  gas  valve  is  opened. 
After  releasing  the  button 

(while  welding  don't  hold  the  button 

pressed!) 

you  can  ignite  the  arc  by  touching  the  workpiece  and  slightly 

lifting an electrode 

(the arc ignition occurs at the moment of lifting an 

electrode).

 

 

NON-CONTACT IGNITION - LAMP (8) IS ON 

The  welding  process  is  initiated  by  pressing  a  control  button  on  the  grip. 

When the button is pressed the gas valve is opened. Releasing the button 
starts  the  ionizer  -  spark-over  between  an  electrode  and  a  workpiece 
should initiate ignition of the arc. If ignition of the arc does not occur within 
2.5s ionizer is turned off and ignition process must be repeated. 

Following  the  arc  ignition

  the  welding  current  increases  during  the  set 

rise  time  Tn  from  minimum  value  (5A)  to  the  set  value  of  spot  welding 
current  Is.  The  current  Is  flows  during  the  set  time  Tpunkt  and  then 
automatically starts the process of decreasing the welding current from the 
Is value to the minimum value (during the set time To). When the current 
reaches  the  minimum  value,  welding  current  is  turned  off  and  the  arc  is 
extinguished. Shielding gas flows still during the set time Tg, then the gas 
valve is being closed. When the gas flows (after extinction of the arc), it is 
possible  to  initiate  the  next  spot  welding  process  without  pressing  the 

Summary of Contents for 200TH

Page 1: ...ENel Sp z o o WROC AW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL200TH USER MANUAL DEALER...

Page 2: ...ble setting of many parameters and simple usage Due to the small dimensions and weight and resistance to large voltage fluctuations the ENEL200TH welder is particularly useful for operation in difficu...

Page 3: ...adjustable in the range of 5 to 170A with a resolution of 1A The rectifier is provided with the ANTISTICK feature facilitating electrode unsticking when it adheres to the works being welded when the...

Page 4: ...the value of the basic current is different from 100 we get pulsating current with the following parameters welding current value will alternate between two values the base current Ib at the TL time...

Page 5: ...welding current in amperes adjustable in the range of 5 200A with a resolution of 1A Ip initial current adjustable as a percentage of the welding current Is within the range 5 50 with a resolution of...

Page 6: ...ol button starts the process of increasing the welding current from the Ip value to the set welding current Is during the time Tn Pressing and releasing the control button once again starts the proces...

Page 7: ...htly lifting an electrode the arc ignition occurs at the moment of lifting an electrode NON CONTACT IGNITION LAMP 8 IS ON The welding process is initiated by pressing a control button on the grip When...

Page 8: ...ires entering a proper three digit PIN code After entering the correct code device switches to the normal operation If you enter a wrong code the device waits for entering the correct code Entering th...

Page 9: ...ter the correct PIN code When the correct code is entered the display shows P 0 0 Press P button the first digit of the code is displayed set 0 with the knob and accept it with P button the second dig...

Page 10: ...ustment range Welding current P40 P60 P100 Input current P40 P60 P100 Output Power P40 P60 P100 Power factor 170A Open Circuit Voltage Power cable cross section Case Enclosure Class Insulation class D...

Page 11: ...5mm2 terminated with an electrode holder K 160 1 2 3m welding cable 1x25mm2 terminated with an electric clamp ZBK35 1 3 Shoulder strap for carrying the rectifier 4 Welding cable with DUALTIG 26 4 weld...

Page 12: ...12 Figure 2 General electric diagram...

Page 13: ...ct the operation mode with button 3 Fig 1 5 Preparation the rectifier for MMA welding with coated electrodes connect the welding cable with electrode holder and the cable terminated with electric clam...

Page 14: ...kpiece initiates ignition of the arc The distance between an electrode and a workpiece shielding gas flow rate and precision of connection the earth wire terminal have a decisive influence on the ease...

Page 15: ...he temperature limiter can operate This cuts off the welding current and lights up the indicator 5 Fig 1 In such case wait until this indicator turns off and then you can continue the welding 8 When t...

Page 16: ...rectifier has been overloaded by exceeding the permitted duty cycle of 60 at currents given in Table 1 the temperature limiter can operate This cuts off the welding current and lights up the indicator...

Page 17: ...n suffocation Often inspect gas cylinder pressure regulator and gas hose All joints should be tight Do not connect the gas cylinder directly to the gas hose without a pressure regulator designed for a...

Page 18: ...plugs and sockets and the condition of the insulation of all current conducting wires and welding holders CAUTION HIGH VOLTAGE OF IONIZER OPERATION Don t press the welding torch switch when working in...

Page 19: ...tch 80 C Thermal switch 70 C Bridge Rectifier Power transformer Control circuit IGBT transistor Capacitor 470 F 450V Electronic kit uP16v2 Electronic kit OPTOv2 Output socket Output choke Control sock...