41
Maintenance
Tab. 8-1 Generator maintenance plan
8.2
Maintenance work
Only authorised personnel are allowed to carry out maintenance tasks.
Carry out all of the maintenance work listed in the maintenance plan ac-
cording to the instructions given in the accompanying operating and main-
tenance instructions provided by the engine manufacturer.
This operating
manual merely describes the instructions that differ from or go beyond
those instructions.
DANGER!
Mortal danger from unintentional generator start up.
Danger of burns and being caught by rotating parts.
► Before accessing the generator you must switch it off and secure it so that
unintentional starting of the machine is prevented under all circumstances.
(see Chapter 7.6 as well).
Cable pull starter
Check the cable pull and func-
tion
X
Fastening and thread-
ed joints
Check for a fixed hold and
damage; replace if necessary
X
Cylinder head and pis-
ton head
Remove any carbon residue
Every 125 hours
2
Fuel tank and fuel filter
Cleaning; change when neces-
sary
every 2 years
2
Fuel lines
Check for cracks and damage;
replace if necessary
every 2 years
2
1) Maintain more frequently if used in a dusty environment.
2) It should only be maintained in one of our authorised workshops.
3) Initially after 20 operating hours
Maintenance work
Maintenance interval according to time or operating
hours [h]
Item
Maintenance step
Daily /
8h
After one
month /
20h
After 3
months /
50h
After 6
months
/ 100h
Annual-
ly / 300h
Maintenance work should be performed by your service partner.