Typical European installation
For installation, proceed as follows:
• Attach the TMT 122 transmitter to a suitable rail or panel.
• Attach thermowell to pipe or process container wall. Install and tighten the thermowell before
applying any pressure.
• Attach and connect appropriate lengths of sensor lead wire from the connection head to the sen-
sor terminal block.
• Tighten the connection head cover. Enclosure covers must be completely engaged in order to
meet explosion-proof area requirements.
• Run the sensor lead wires from the sensor assembly to the TMT 122 transmitter.
• Attach the sensor wires to the TMT 122 transmitter.
fig. 4:
Installing the TMT 122 DIN rail transmitter
2
1
35mm
IEC 60715