3. 3 Process connection
The following table illustrates the versions of Thermophant T.
TTR31
TTR35
T09-TTR31xxx-17-xx-xx-en-000
Field of applica-
tion
Monitoring, display and control of process temperatures
Monitoring, display and con-
trol of process temperatures
in hygienic processes
Process connec-
tion
Item A
Version without proc-
ess connection (’w’).
Suitable welding
bosses and coupling
(see Section 6)
Item B
Version with thread
process connection
ANSI ¼" NPT
(
m
= AF14) and
½" NPT (
m
= AF27)
Item C
Version with thread
process connection
G ¼A (
n
= AF14) and
G ½A (
n
= AF27) as
per ISO 228
Item D
Adapter concept - version
with M24x1.5 thread for
adapters with process con-
nection for hygienic processes
(see Section 6.1.2)
Sensor length L
Version L in 100 and 200 mm (3.94 and 7.87"), version L = 50 mm (1.97") only with reduced sensor tip
Measuring range