background image

TTR31, TTR35

Operation

Hauser

17

5. 2  Operation with PC and Readwin

®

 2000

T09-TTR31xxx-04-xx-xx-en-004

Fig. 10: Operation with PC

5.2.1

Additional operating options

In addition to the operating options listed in the previous "On-site operation" section, the Read-
Win

®

 2000 configuration software provides further information on the Thermophant T:

Function group

Description

SERV

Number of switch changes for output 1

Number of switch changes for output 2

Device status 

INFO

Tag number

 Order code

Limit switch serial number

Sensor serial number

Electronics serial number

Device release
(change status)

Hardware version

Summary of Contents for Thermophant T TTR31

Page 1: ...BA201R 09 en 02 05 51009833 Release 01 01 00 Operating manual Thermophant T TTR31 TTR35 Temperature switch...

Page 2: ...voltage version with M12 connector 8 4 2 DC voltage version with valve connector 8 5 Operation 9 5 1 On site operation 9 5 2 Operation with PC and Readwin 2000 17 6 Accessories 18 6 1 Adapter concept...

Page 3: ...d according to the standards IEC 61508 and IEC 61511 1 FDIS The device version with PNP switch output and additional analog output is equipped with fault detection and fault prevention facilities with...

Page 4: ...9 TTR31xxx 18 xx xx xx 000 Fig 1 Nameplate for device identification as example Note The release number indicates the change status of the device A change in the last two figures does not have any aff...

Page 5: ...the goods delivered are complete and nothing is missing Storage Storage temperature 40 C to 85 C 40 F to 185 F 3 2 Dimensions T09 TTR31xxx 06 xx xx en 000 Fig 2 Dimensions in mm inches Version L in 1...

Page 6: ...Item A Version without proc ess connection w Suitable welding bosses and coupling see Section 6 Item B Version with thread process connection ANSI NPT m AF14 and NPT m AF27 Item C Version with thread...

Page 7: ...or use in hygienic processes Mounting instructions Installation at angle pieces against the direction of flow Fig 3 Item A Installation in smaller pipes inclined against the direction of flow Fig 3 It...

Page 8: ...diagnosis break contact with adjustment DESINA A3 PNP switch output with additional analog output A3 PNP switch output with additional analog output PIN assignment with DESINA setting Note DESINA Chap...

Page 9: ...ated by means of three keys The digital display and the light emitting diodes LED support navigation in the operating menu T09 TTR31xxx 19 xx xx en 001 Fig 6 Position of operating elements and possibi...

Page 10: ...with the E key p Enter or change parameters with the or key Then return to Function with the E key Note If software locking is enabled it must be disabled before making entries or changes q Press the...

Page 11: ...n Endress Hauser 11 5 1 2 Structure of the operating menu The structure below shows all the possible fields of the operating menu T09 TTR31xxx 19 xx xx xx 003 Fig 8 Operating menu A function groups B...

Page 12: ...56 56 56 56 56 56 5 5 5 5 5 5 5 5 PV measured value display PVRO measured value display rotated 180 SP set switch point display SPRO set switch point display rotated 180 OFF display off OFFR display...

Page 13: ...s temperature range NO contact or NC contact This switch function is freely selectable Factory setting if no customer specific settings have been ordered Switch point SP 1 45 Switch back point RSP 1 4...

Page 14: ...5 5 5 58 58 58 58 Switch point value 010 010 010 010 Switch point 49 5 to 150 C 57 1 to 302 F in increments of 0 1 C 0 18 F 5 5 5 5 58 58 58 58 Switch back point value 010 010 010 010 Switch back poi...

Page 15: ...nts of 0 1 C 0 18 F 2 3 2 3 2 3 2 3 Temperature applied for 4 mA LRV 010 010 010 010 Take temperature value as lower range value not via PC software 2 3 2 3 2 3 2 3 Temperature applied for 20 mA URV 0...

Page 16: ...entries to the fac tory setting 63 63 63 63 Revision counter 0 0 0 0 Increases by 1 with each configuration 3 3 3 3 Last device status 0 0 0 0 Displays the last device status to occur 0 8 8 8 8 if out...

Page 17: ...sted in the previous On site operation section the Read Win 2000 configuration software provides further information on the Thermophant T Function group Description SERV Number of switch changes for o...

Page 18: ...iven in mm inches 6 1 Adapter concept for TTR35 The process connection is an adapter and the sensor module has an adapter thread see Section 3 3 process connection As a result the process connection c...

Page 19: ...1 2 adapter versions The maximum torque is 80 Nm The thread can become loose if exposed to severe strain through pressure and temperature For this reason the air tightness must be checked regularly an...

Page 20: ...g boss with sealing taper TTR35 order numbers for hygiene adapter versions Version LB order no 52023996 Version LL order no 52023997 Version PH order no 52023999 Version PL order no 52023998 Version H...

Page 21: ...752 T09 TSM470BX 06 09 00 en 000 G process connection Seal moveable coupling material of parts in contact with process 316L Order no 51004753 T09 TSM470AX 06 09 00 en 001 M 12x1 plug in jack Self made...

Page 22: ...cations order number 52018763 Display gn device operational ye1 switch status 1 ye2 switch status 2 Core colours 1 BN brown 2 WH white 3 BU blue 4 BK black T09 TTR31xxx 00 00 xx xx 001 Configuration k...

Page 23: ...sured value is reliable Code Explanation E011 Device configuration faulty E012 Error in measurement or underreach overreach in SIL mode E015 Error in EEPROM E019 Power supply has undervoltage overvolt...

Page 24: ...he permitted range not SIL mode W250 Number of switch cycles exceeded W270 Short circuit and overload at output 1 W280 Short circuit and overload at output 2 XX Change in the main version Compatibilit...

Page 25: ...switches off status as if not supplied with power switch open 8 2 Output Switching capacity Switch status ON Ia 250 mA Switch status OFF Ia 1 mA Switching cycles 10 000 000 Voltage drop PNP 2 V Overlo...

Page 26: ...es Chap 6 2 1 Chap 6 2 3 order no 51004751 51004753 and neck tube length min 20 mm with process connection Process pressure limits p T load diagram as per DIN 43763 or Dittrich T09 TSM470ZZ 05 00 xx e...

Page 27: ...umweltgef hrlich biogef hrlich radioaktiv Please tick should one of the above be applicable include security sheet and if necessary special handling instructions Zutreffendes ankreuzen trifft einer de...

Page 28: ...www endress com worldwide BA201R 09 en 02 05 51009833 CCS FM6 0 SGML...

Reviews: