Endress+Hauser Soliswitch FTE20 Operating Instructions Manual Download Page 6

Safety instructions

Soliswitch FTE20

6

Hauser

1.2.5 

Tool symbols

Symbol

Meaning

  A0011220

Flat blade screwdriver

  A0011221

Allen key

  A0011222

Open-ended wrench

  A0013442

Torx screwdriver

Safety instructions

2.1 

Requirements for the personnel

The personnel for installation, commissioning, diagnostics and maintenance must fulfill the
following requirements:

Trained, qualified specialists must have a relevant qualification for this specific function and
task

Are authorized by the plant owner/operator

Are familiar with federal/national regulations

Before beginning work, the specialist staff must have read and understood the instructions in
the Operating Instructions and supplementary documentation as well as in the certificates
(depending on the application)

Following instructions and basic conditions

The operating personnel must fulfill the following requirements:

Being instructed and authorized according to the requirements of the task by the facility's
owner-operator

Following the instructions in these Operating Instructions

2.2 

Designated use

The Soliswitch FTE20 must only be used as a point level switch for specific bulk solids (see
Technical Data) (

®

  

ä

 23). Comply with the specifications of EN50281-1-2 with regard to

temperatures and accumulations of dust.
• The device may only be operated when installed.
• The manufacturer accepts no liability for damages resulting from incorrect use or use other

than that designated. It is not permitted to convert or modify the device in any way.

Summary of Contents for Soliswitch FTE20

Page 1: ...Operating Instructions Soliswitch FTE20 Point level switch BA01069F 09 EN 01 12 71186553...

Page 2: ......

Page 3: ...eptance transport storage 9 4 2 Installation conditions 9 4 3 Installation instructions 11 4 4 Post installation check 15 5 Wiring 16 5 1 Connection instructions 16 5 2 Quick wiring guide 16 5 3 Post...

Page 4: ...symbol alerts you to a dangerous situation Failure to avoid this situation can result in minor or medium injury NOTICE A0011192 EN NOTICE This symbol contains information on procedures and other fact...

Page 5: ...additional information A0011194 Reference to documentation Refers to the corresponding device documentation A0011195 Reference to page Refers to the corresponding page number A0011196 Reference to gr...

Page 6: ...the Operating Instructions and supplementary documentation as well as in the certificates depending on the application Following instructions and basic conditions The operating personnel must fulfill...

Page 7: ...ertaining to repair of an electrical device Use original spare parts and accessories from Endress Hauser only Hazardous area To eliminate a danger for persons or for the facility when the device is us...

Page 8: ...and manufacturer s address 3 2 Certificates and approvals An overview of all the approvals available is provided in the Technical data section CE mark Declaration of Conformity The device is designed...

Page 9: ...or the content damaged Is the delivery complete Compare the scope of delivery against the information on your order form 4 1 2 Transport and storage Please note the following Pack the device so that...

Page 10: ...ss Hauser 1 3 2 4 200 7 87 mm in 5 A0017073 2 Correct installation positions of the point level switch 1 Vertical from the top 2 Angled from the top 3 From the side 4 From the side with protective cov...

Page 11: ...Ambient temperature range 20 to 60 C 4 to 140 F Medium temperature range 20 to 80 C 4 to 176 F More information is provided in the Technical data section 23 4 3 Installation instructions NOTICE The d...

Page 12: ...allation of the standard version 1 Sealing ring 60x48x3 mm 2 36x1 89x0 12 in 2 Open ended wrench AF 60 NOTICE Function of device with hinged rotating paddle restricted by transport lock Remove the tra...

Page 13: ...on Endress Hauser 13 1 2 1 2 3 A0017363 5 Installation of the version with the hinged rotating paddle 1 Sealing ring 2 Open ended wrench AF 32 4 3 1 Turning the housing to the right position A0017364...

Page 14: ...he dimensions are provided in the Technical data section 30 A0018473 7 Installation of the flange version 4 3 3 Mounting the weather protection cover The weather protection cover is available as an ac...

Page 15: ...t the cover from opening Additional installation instructions for the hazardous area are provided in the separate Ex documentation for the device optional T10 A0017368 9 Tightening the cover securing...

Page 16: ...lose to the device within easy reach and marked as a circuit breaker An overload protection element rated current 10 A is required for the power cable If replacing an older Soliswitch FTE3x with a new...

Page 17: ...tput signal FTE20 and FTE20 with rotation monitoring Lamp not lit Shaft turns No Full signal Shaft turns Refill signal B output signal FTE20 and FTE20 with rotation monitoring Lamp lit Shaft does not...

Page 18: ...Wiring Soliswitch FTE20 18 Endress Hauser 5 2 2 Inserting the cable 1 2 A0017367 11 Remove the housing cover 3 4 5 A0017365 12 Guide the cable through the cable entries...

Page 19: ...Does the supply voltage match the specifications on the nameplate 1 8 20 to 28 V DC 24 V AC 115 V AC 230 V AC Are the mounted cables connected correctly and strain relieved Are the cable glands secure...

Page 20: ...addle The disk s viewing area is lit up by an LED to make it easier to see The rotational movement of the disk and therefore also the shaft can be checked through an inspection opening in the cover of...

Page 21: ...369 16 Testing the internal switch 7 Commissioning 7 1 Post installation and post connection check Checklists Post installation check 15 Post connection check 19 7 2 Setting the switching pressure The...

Page 22: ...nitoring of the FTE20 optional Power supply Motor Output signal of full sensor On Shaft turns On Shaft does not turn rotating paddle is covered Full On Shaft does not turn rotating paddle is not cover...

Page 23: ...length 9 1 2 Measuring range The measuring range depends on the installation location of the Soliswitch FTE20 and the selected length of the shaft 75 to 300 mm 2 95 to 11 81 in or the rope extension u...

Page 24: ...rminals with spring terminal design Permitted cable cross sections Rigid 0 2 to 2 5 mm 24 to 14 AWG Flexible 0 2 to 2 5 mm 24 to 14 AWG Flexible with wire end ferrule without plastic ferrule 0 5 to 2...

Page 25: ...on From below Cable entry must point downwards In direction of solids flow Installation socket too long Horizontal with shaft length 300 mm 11 8 in 9 5 2 Special mounting instructions Side load on the...

Page 26: ...mmunity As per IEC 61326 1 industrial environments Interference emissions As per IEC 61326 1 Class B 9 6 5 Electrical safety Protection class I overvoltage category II pollution level II 9 6 6 Operati...

Page 27: ...ons 103 4 06 113 4 45 SW AF 60 105 4 13 157 6 18 131 5 16 130 5 12 126 8 4 99 101 8 4 01 2000 78 7 108 4 25 28 8 1 13 136 8 5 39 130 5 12 L 25 0 98 L 40 1 57 L 27 5 1 08 L 52 5 2 07 mm in 1 2 A 1 A001...

Page 28: ...on NPT 1 NPT 1 G 1 B Process connection G only available with hinged rotating paddle L Length of shaft 75 to 300 mm 2 95 to 11 81 in 9 8 2 Weight Version part Weight approx FTE20 with shaft 100 mm 3 9...

Page 29: ...by a reflector disk fitted on drive shaft of the paddle and can be monitored through a sight opening in the drive terminal cover The disk s viewing area is lit up by an LED to make it easier to see I...

Page 30: ...s Hauser 9 10 1 Device specific accessories Accessories Description Flange version 150 5 91 150 5 91 18 0 71 48 1 89 2 0 08 mm in 15 0 59 15 0 59 A0018472 20 Dimensions of the flange connection Order...

Page 31: ...ive cover Used to protect the measuring device from the adverse effect of the weather when fitted in the roof of a silo 6 2 2 4 4 175 6 89 201 5 7 93 298 5 11 75 103 4 06 221 5 8 72 mm in A0017694 21...

Page 32: ...BA01069F 09 EN 01 12 71186553 EH COSIMA ProMoDo...

Reviews: