Prothermo NMT539
Operation
Hauser
35
Code
Display
Details
1
2
3
4
5
7
a
6
A0038550
13
Gas offset
a
VH48 gas offset 300 mm (11.81 in) (Default)
1
To NMT539 converter
2
Temperature element
3
Gas phase
4
Exclusion range (see Note)
5
Level
6
Liquid phase
7
To tank bottom
Although temperature elements in this range are in the gas
phase, they are excluded from average gas temperature
calculations in order to avoid effects from the interface between
the liquid phase and the gas phase.
VH49
Liquid Offset
(Liquid offset)
Item type
Read / Write
Default
300 mm (11.81 in)
Range
0 to 99
999 mm
1
2
3
4
5
7
a
6
A0038551
14
Liquid offset
a
VH48 gas offset 300 mm (11.81 in) (Default)
1
To NMT539 converter
2
Temperature element
3
Gas phase
4
Exclusion range (see Note)
5
Level
6
Liquid phase
7
To tank bottom
Although temperature elements in this range are in the liquid
phase, they are excluded from average liquid temperature
calculations in order to avoid effects from the interface between
the liquid phase and the gas phase.