11 Description of device functions
Prosonic Flow 92
66
EHauser
11.2.1
Group MEASUREMENT
Measurement
Þ
Function
Measurement
Note!
When the cursor points to the MEASUREMENT group tab (a), the measurement screen is not active.
Move the cursor onto the screen by pressing the
T
key (b).
Unit
Use this function to select the unit for displaying the volume flow or the flow
velocity.
The unit you select here is also valid for the current output.
Metric options:
L/s – L/min – L/h – ML/d – m3/s – m3/min – m3/h – Mm3/d – BBL/s – BBL/min
– BBL/h – MBBL/d – m/s – AI % – AO %
US options:
gal/s – gal/min – gal/h – Mgal/d – ft3/s – ft3/min – ft3/h – Mft3/d – BBL/s –
BBL/min – BBL/h – MBBL/d – ft/s – AI % – AO %
Factory setting:
– Volume flow: L/s
– Flow velocity: m/s
Reset (+Totalizer)
If you activate this function, the value of the +Totalizer (forward flow) is set to
the value which is defined in PRESET TOTALIZER, see Page 73.
Reset (-Totalizer)
If you activate this function, the value of the -Totalizer (reverse flow) is set to
the value which is defined in PRESET TOTALIZER, see Page 73.
F06-92xxxx
xx-07-06-xx-
xx-002