Installation
6.1
Installation conditions
For mechanical reasons and to protect the pipe, support is recommended for heavy sensors (e.g.
with a hot-tap retractable assembly).
6.1.1
Mounting position
Orientation
The direction of the arrow on the sensor helps you to install the sensor according to the flow
direction.
Orientation
Recommendation
Vertical orientation
A0017337
1) 2)
Horizontal orientation, transmitter head up
A0015589
Horizontal orientation, transmitter head
down
A0015590
3)
Inclined mounting position, transmitter head
down
a
A0015773
4)
1)
In the case of saturated or unclean gases, upward flow in a vertical pipe section is preferred to minimize condensation
or contamination.
2)
Not recommended in the case of extreme vibrations or unstable installations.
3)
Suitable only for clean and dry gases. If buildup or condensate are always present: Mount the sensor in an inclined
position.
4)
Select inclined mounting position (
a
= approx. 135°) if the gas is very wet or saturated with water.
Requirement for pipework
The measuring device must be professionally installed, and the following points must be
observed: