Proline Prosonic Flow P 500
52
Hauser
Special mounting
instructions
Protective cover
146 (5.75)
48 (1.9)
12 (0.47)
280 (11.0)
255 (10.0)
134 (5.3)
30 (1.18)
A0029553
48
Protective cover for Proline 500; engineering unit mm (in)
Environment
Ambient temperature range
Transmitter
• Standard:–40 to +60 °C (–40 to +140 °F)
• Optional order code for "Test, certificate", option JN:
–50 to +60 °C (–58 to +140 °F)
Readability of the local display
–20 to +60 °C (–4 to +140 °F)
The readability of the display may be impaired at temperatures outside
the temperature range.
Sensor
DN 15 to 65 (½ to 2½")
–40 to +150 °C (–40 to +302 °F)
DN 50 to 4000 (2 to 160")
• Standard:–40 to +80 °C (–40 to +176 °F)
• Optional: 0 to +170 °C (+32 to +338 °F)
Sensor cable (connection between
transmitter and sensor)
DN 15 to 65 (½ to 2½")
Standard (TPE
): –40 to +80 °C (–40 to +176 °F)
DN 50 to 4000 (2 to 160")
• Standard (TPE halogen-free): –40 to +80 °C (–40 to +176 °F)
• Optional (PTFE
): –50 to +170 °C (–58 to +338 °F)
1)
Armored version also available for order
In principle, it is permitted to insulate the sensors mounted on the pipe. In the case of insulated
sensors, make sure that the process temperature does not exceed or drop below the specified
cable temperature.
‣
If operating outdoors:
Avoid direct sunlight, particularly in warm climatic regions.
You can order a weather protection cover from Hauser. → 73.
Storage temperature
The storage temperature for all components (except the display modules) corresponds to the
ambient temperature range → 52.
Display modules
–40 to +80 °C (–40 to +176 °F)