Proline Prosonic Flow 90U, 90W, 91W, 93C, 93U, 93W

32

E Hauser

Operating conditions: Process

Medium temperature range

• Flowrate measuring sensors Prosonic Flow W (clamp-on):

–20 to +80 °C (optional 0 to +130 °C)

• Flowrate measuring sensors Prosonic Flow U (clamp-on):

–20 to +80 °C

• Flowrate measuring sensors Prosonic Flow W (Insertion):

–40 to +80 °C

• Prosonic Flow C Inline:

Measuring pipe: –10 to +60 °C (epoxy coated)
Flowrate measuring sensors Prosonic Flow W (Inline): –40 to +80 °C

• Sound velocity measuring sensors DDU 18:

–40 to +80 °C

• Wall thickness measuring sensor DDU 19:

0 to +60 °C

Medium pressure range 
(nominal pressure)

• Perfect measurement requires that the static fluid pressure is higher than vapor pressure.
• Max. nominal pressure Prosonic Flow W (insertion): PN 16 (232 psi).

Pressure loss

There is no pressure loss.

Summary of Contents for Proline Prosonic Flow 90U

Page 1: ...rea ATEX FM CSA Approvals in the food industry hygiene sector Drinking water approval for Prosonic Flow C Connection to process control system HART PROFIBUS PA FOUNDATION Fieldbus Your benefits Proson...

Page 2: ...ectrical connection sensor connecting cable Prosonic Flow 91 22 Supply voltage power supply 22 Cable entry 22 Cable specifications 23 Power consumption 23 Power supply failure 23 Potential equalizatio...

Page 3: ...as a measure of fluid quality Application specific configuration of the Prosonic Flow can be carried out locally with the aid of the Quick Setup menu System design Measuring system The Prosonic Flow...

Page 4: ...rties the Prosonic Flow sensors are particularly suited to certain nominal diameter ranges and pipe wall thicknesses For this reason various sensor types are offered for Prosonic Flow W and U for thes...

Page 5: ...e displays an insufficient signal strength reduce the number of the traverses Dual channel measuring devices Prosonic Flow 93 has two measuring channels which are independent of one another In other w...

Page 6: ...fferent types of installation A0001160 a Cable for power supply b Signal cable outputs Note Observe the recommendations in the Sensor arrangement section Page 4 The following possibilities for outputt...

Page 7: ...ANSI 316 SS ANSI 347 SS ANSI 410 SS ANSI 430 ALLOY C PVC PE LDPE HDPE GRP PVDF PA PP PTFE GLASS PYREX ASBESTOS CEMENT CARBON STEEL DUCTILE IRON Lining CEMENT RUBBER TAR EPOXY Additional accessories If...

Page 8: ...the aid of welding sockets For this boreholes are required in the pipe into which the supports for the flowrate measuring sensors are welded In a second step the flowrate measuring sensors are screwe...

Page 9: ...93 C Inline measuring system measures with guaranteed and verifiable accuracy Prosonic Flow C Inline makes it possible to achieve high accuracy of the ultrasonic flow measuring system and also offers...

Page 10: ...eas Two line LCD display Configuration with keys Quick Setup All outputs are galvanically isolated from the power supply measuring circuit and each other Volume and sound velocity measurement Designed...

Page 11: ...ge 20 to 80 C optional 0 to 130 C Degree of protection IP 67 IP 68 optional Sensor holder made of stainless steel Prosonic Flow W Insertion version F06 9xWINxxx 21 05 06 xx 000 Insertion flowrate meas...

Page 12: ...tput Active passive selectable galvanically isolated time constant selectable 0 05 to 100 s full scale value adjustable temperature coefficient typ 0 005 o r C resolution 0 5 A Active 0 4 to 20 mA RL...

Page 13: ...coefficient typ 0 005 o r C resolution 0 5 A Active 0 4 to 20 mA RL 700 for HART RL 250 Passive 4 to 20 mA max 30 V DC Ri 150 Pulse frequency output Active passive selectable galvanically isolated Act...

Page 14: ...trol totalizer control zero point adjustment control display value Bus address can be set via DIP switch on device FOUNDATION Fieldbus interface for Prosonic Flow C FOUNDATION Fieldbus H1 IEC 61158 2...

Page 15: ...ansmitter wall mount housing Cable cross section max 2 5 mm2 a Cable for power supply 85 to 260 V AC 20 to 55 V AC 16 to 62 V DC power consumption 18 VA 10 W Terminal No 1 L1 for AC L for DC Terminal...

Page 16: ...l No inputs outputs 20 21 22 23 24 25 26 27 Fixed communication boards fixed assignment 93 A Frequency output HART current output 93 B Relay output Relay output Frequency output HART current output 93...

Page 17: ...terminal for power supply cable d Terminal connector for power supply No 1 2 terminal assignment e Signal cable f Ground terminal for signal cable g Terminal connector for signal cable No 24 27 termin...

Page 18: ...L for DC Terminal No 2 N for AC L for DC b PROFIBUS PA line Terminal No 26 PA Terminal No 27 PA c Ground terminal for protective earth d Ground terminal for signal cable shield e Service connector for...

Page 19: ...C b PROFIBUS PA line Terminal No 26 PA Terminal No 27 PA c Ground terminal for protective earth d Ground terminal for signal cable shield e Service connector for connecting service interface FXA193 Fi...

Page 20: ...able Terminal No 26 FF with integrated reverse polarity protection Terminal No 27 FF with integrated reverse polarity protection c Ground terminal for protective earth d Ground terminal for fieldbus c...

Page 21: ...sor connecting cable Prosonic Flow 90 93 Connecting power sensor cables in the connection compartment F06 9xxxxxxx 04 06 06 xx 000 A View A wall mount housing non hazardous areas Ex Zone 2 1 Channel 1...

Page 22: ...al i Cable holder Supply voltage power supply Transmitter 85 to 260 V AC 45 to 65 Hz 20 to 55 V AC 45 to 65 Hz 16 to 62 V DC Measuring sensors Powered by the transmitter Cable entry Power supply and s...

Page 23: ...well as NAMUR recommendation NE 21 Signal and power cable Caution Grounding is by means of the ground terminals provided for this purpose inside the connection housing Keep the stripped and twisted le...

Page 24: ...he clamp on version on a DN 250 pipe for the Insertion version single path version and on a DN 400 pipe for the Insertion version dual path version The verification applies under reference operating c...

Page 25: ...DN 200 c Pipe diameter DN 50 Max measured error for wet calibration and verification of accuracy in of reading A0003720 en a Pipe diameter DN 200 b Pipe diameter DN 50 DN 200 c Pipe diameter DN 50 Re...

Page 26: ...ipe outlet in a down pipe A0001103 Applies to all sensor versions Down pipes Notwithstanding the above the installation proposal below permits installation in an open down pipe Pipe constrictions or t...

Page 27: ...d up Horizontal In the recommended installation range in a horizontal installation position View B gas and air accumulation at the pipe cover and problematic build ups at the bottom of the pipe have a...

Page 28: ...ng fluid A coupling fluid is required to ensure the acoustic link between the sensor clamp on version and the piping This is applied to the sensor surface during commissioning Periodic replacement of...

Page 29: ...4 Spring 5 Large circlip 6 Sensor neck 7 Sensor element 8 Sensor holder Sensor replacement Prosonic Flow C Inline The active part of the sensor can be replaced without interrupting the process Prosoni...

Page 30: ...ns above the dimensioning line single path version dimensions under the dimensioning line dual path version and Prosonic Flow C 1 Valve 2 Pump 3 Two pipe bends in different directions Length of connec...

Page 31: ...nsmitter at a shady location Avoid direct sunlight particularly in warm climatic regions Storage temperature The storage temperature corresponds to the ambient temperature range of the measuring trans...

Page 32: ...Prosonic Flow W Insertion 40 to 80 C Prosonic Flow C Inline Measuring pipe 10 to 60 C epoxy coated Flowrate measuring sensors Prosonic Flow W Inline 40 to 80 C Sound velocity measuring sensors DDU 18...

Page 33: ...Ensure that the ambient temperature does not exceed or undershoot the permitted range of 20 C to 60 C or optionally 40 C to 60 C Install the device at a shady location Avoid direct sunlight Always ins...

Page 34: ...n the housing Pipe mounting and panel mounting A0005256 en A Pipe mounting the wall mount housing B Installation of the wall mount housing in a control panel Caution If a pipe which is heated under no...

Page 35: ...90U 90W 91W 93C 93U 93W Endress Hauser 35 Dimensions of field housing Prosonic Flow 91 A0006063 en Dimensions of pipe mounting Prosonic Flow 91 A0005819 en Esc E 190 178 150 113 80 100 52 8 6 M8 200 1...

Page 36: ...pacing can be determined using Quick Setup b Pipe outer diameter defined by the application Prosonic Flow U clamp on version for small nominal diameters A0001152 en a Sensor spacing can be determined...

Page 37: ...pacing can be determined using Quick Setup c Path length can be determined using Quick Setup Dual path version A0001219 en B View B a Pipe outer diameter defined by the application b Sensor spacing ca...

Page 38: ...350 548 350 182 550 505 350 546 348 181 550 520 14 544 346 179 9 550 533 4 400 590 400 208 600 565 400 589 398 207 600 580 16 587 396 205 9 600 596 9 18 629 445 231 4 650 635 500 676 500 260 650 670...

Page 39: ...800 1786 1800 936 2340 2115 1800 1776 1788 929 8 2340 2130 72 1778 1790 930 8 2340 2197 1 2000 1961 2004 1042 1 2600 2265 2000 1954 1996 1037 9 2600 2325 2000 1943 1984 1031 7 2600 2345 80 1949 1990 1...

Page 40: ...C Inline Sensor housing 1 4404 DIN 17440 316L AISI Weld in parts 1 4404 DIN 17440 316L AISI Measuring pipe ST 37 2 carbon steel Prosonic Flow DDU 18 and DDU 19 Sensor housing 1 4301 DIN 17440 304 AISI...

Page 41: ...Flow 91 Local operation via three operating keys S O F Quick Setup menu for quick commissioning Prosonic Flow 93 Local operation with three optical sensor keys S O F Application specific Quick Setup m...

Page 42: ...ocedures carried out and is certified and registered by the Fieldbus Foundation The device thus meets all the requirements of the following specifications Certified to FOUNDATION Fieldbus Specificatio...

Page 43: ...structions Prosonic Flow 90 PROFIBUS PA BA074D 06 en and BA075D 06 en Operating Instructions Prosonic Flow 93 BA070D 06 en and BA071D 06 en Operating Instructions Prosonic Flow 93 PROFIBUS DP PA BA076...

Page 44: ...ernational Headquarters Endress Hauser GmbH Co KG Instruments International Colmarer Str 6 79576 Weil am Rhein Deutschland Tel 49 76 21 9 75 02 Fax 49 76 21 9 75 34 5 www endress com info ii endress c...

Reviews: